跳到正文
原文
Nature 健康护理主题·· 29 天前AI 评分42

术后光谱头颅CT虚拟单能成像权衡:双中心读者研究

Virtual monoenergetic imaging trade-offs in postoperative spectral head CT: a two-center reader study

AI 导读

一项双中心回顾性研究评估了93例患者术后光谱头颅CT中不同虚拟单能成像(VMI)能级的图像质量。70 keV VMI在整体图像质量、手术床脑实质显著性及诊断可接受性上获得读者最高评分,而60 keV对比噪声比(CNR)最高,100 keV噪声及伪影抑制效果最佳。作者指出,在将这些结果应用于特定临床工作流程前,仍需进行诊断性能验证。

正文

Scientific Reports (2026) Cite this article

We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.

Abstract

Postoperative non-contrast spectral head CT permits retrospective virtual monoenergetic imaging (VMI), but the energy level that best balances objective and reader-rated image quality is uncertain. We evaluated 93 patients who contributed 120 postoperative examinations using conventional images and VMIs at 60, 70, 80, 90, and 100 keV. Image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and independent ratings by two neuroradiologists were analyzed with mixed-effects models reflecting the hierarchical data structure. CNR was highest at 60 keV (1.62 ± 0.39), whereas image noise was lowest at 100 keV (4.27 ± 0.49 HU). The 70-keV VMI had the highest reader scores for overall image quality, operative-bed parenchymal conspicuity, and diagnostic acceptability, whereas 100 keV had the highest artifact-suppression score. Quadratic-weighted kappa values ranged from 0.859 to 0.986. Thus, no single VMI energy optimized all image-quality properties: 60 keV maximized measured CNR, 70 keV produced the most favorable reader ratings across three routine-review domains, and 100 keV minimized noise and maximized artifact suppression. Diagnostic-performance validation is required before these findings inform a task-specific clinical workflow.

Acknowledgements

None.

Funding

No specific funding was received for this study.

Author information

Authors and Affiliations

  1. Department of Radiology, Zigong First People’s Hospital, Zigong, 643000, People’s Republic Of China

    Yujian Liu, Jie Yang & Jianquan Zhong

  2. Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, People’s Republic Of China

    Hao Wu, Qiao Zheng & Hongwei Liang

Authors

  1. Yujian Liu
  2. Jie Yang
  3. Jianquan Zhong
  4. Hao Wu
  5. Qiao Zheng
  6. Hongwei Liang

Corresponding author

Correspondence to Yujian Liu.

Ethics declarations

Competing interests

The authors declare no competing interests.

Ethics approval and consent to participate

This retrospective two-center study was approved by the Institutional Review Board of Zigong First People’s Hospital (approval No. (M)2026-050; approval date: May 8, 2026). At the First Affiliated Hospital of Chongqing Medical University, the Ethics Committee waived the requirement for formal ethics approval because the study was retrospective, involved only de-identified clinical imaging data, and posed minimal risk to participants. Written informed consent was waived for all included patients by the respective institutional review bodies. All procedures were conducted in accordance with relevant institutional guidelines and regulations and with the Declaration of Helsinki.

Consent for publication

Not applicable.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Liu, Y., Yang, J., Zhong, J. et al. Virtual monoenergetic imaging trade-offs in postoperative spectral head CT: a two-center reader study. Sci Rep (2026). https://doi.org/10.1038/s41598-026-77305-y

Download citation

  • Received: 21 July 2026

  • Accepted: 19 October 2026

  • Published: 22 October 2026

  • DOI: https://doi.org/10.1038/s41598-026-77305-y

Keywords

来源:Nature 健康护理主题 · nature.com