4-mm超短种植体周围骨应力与应变分布受咬合负载及牙冠材料影响:三维有限元分析

Effect of occlusal loading and crown material on stress and strain distribution in bone around 4-mm ultra-short implants: a 3D-FEA

AI 导读

一项三维有限元分析评估了咬合负载、修复体配置及牙冠材料对4-mm超短种植体周围骨应力和应变的影响。研究显示,斜向加载显著增加了单冠模型的皮质骨和骨小梁应力,而加入食团模拟可缓解该效应;双冠连冠配置在斜向加载下的植入体周围ROI结果低于单冠配置,但无法隔离联冠本身的独立因果效应。结论强调这些比较结果不能确立临床优越性或生物力学可靠性,需进一步实验和临床验证。

正文

Scientific Reports (2026) Cite this article

We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.

Abstract

Ultra-short (4-mm) dental implants represent a minimally invasive solution for the rehabilitation of posterior atrophic regions; however, concerns remain regarding stress and strain concentration in bone around implants under functional loading. This study aimed to evaluate the influence of occlusal loading conditions, prosthetic configuration, and crown material on stress and strain distribution using three-dimensional finite element analysis (3D-FEA). Three-dimensional finite element models of single-crown restorations and the splinted two-crown configuration supported by 4-mm ultra-short implants were developed. Zirconia and composite resin crowns were evaluated under vertical and 30° oblique loading, with and without a simulated food bolus. The bolus was assigned a Young’s modulus of 10 MPa and a Poisson’s ratio of 0.30. Primary outcomes were volume-weighted mean von Mises stress and equivalent elastic strain within a fixed 0.50-mm peri-implant volumetric region of interest (ROI). Mesh convergence was assessed using three nominal local refinement levels and a 5% acceptance threshold. In single-crown models without bolus, oblique loading increased cortical ROI stress from approximately 10.01 to 43.02 MPa and trabecular ROI stress from approximately 4.95 to 12.35 MPa. With bolus interposition, corresponding oblique values decreased to approximately 19.57 and 5.63 MPa. In models of the splinted two-crown configuration, cortical ROI stress under oblique loading ranged from 8.63 to 10.43 MPa. Zirconia and composite resin produced nearly identical ROI outcomes in the single-crown configurations, whereas a modest configuration-specific difference was observed under oblique loading in the splinted two-crown configuration. All primary outcomes met the 5% convergence criterion. Within the assumptions of this finite element model, loading direction and prosthetic configuration had greater effects on peri-implant stress and strain than crown material. Bolus interposition reduced the ROI outcomes under oblique loading. Under the modeled oblique conditions, the splinted two-crown configuration was associated with lower peri-implant ROI outcomes than the single-crown configuration; however, the different total loads prevent isolation of splinting as an independent causal factor. These comparative findings do not establish clinical superiority or biomechanical reliability and require experimental and clinical validation.

Funding

The Authors received no funding for this work.

Author information

Authors and Affiliations

  1. Department of Industrial Engineering, University of Naples Federico II, 80125, Naples, Italy

    Fabrizio Renno & Antonio Lanzotti

  2. Department of Neuroscience, Reproductive Science and Dentistry, University of Naples Federico II, 80138, Naples, Italy

    Roberta Gasparro, Mauro Mariniello, Angelo Aliberti & Pietro Ausiello

  3. Department of Bioscience Research, College of Dentistry, University of Tennessee Health Science Center, Memphis, TN, USA

    Franklin Garcia-Godoy

Authors

  1. Fabrizio Renno
  2. Roberta Gasparro
  3. Mauro Mariniello
  4. Angelo Aliberti
  5. Franklin Garcia-Godoy
  6. Antonio Lanzotti
  7. Pietro Ausiello

Corresponding author

Correspondence to Angelo Aliberti.

Ethics declarations

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Renno, F., Gasparro, R., Mariniello, M. et al. Effect of occlusal loading and crown material on stress and strain distribution in bone around 4-mm ultra-short implants: a 3D-FEA. Sci Rep (2026). https://doi.org/10.1038/s41598-026-76024-8

Download citation

  • Received: 17 April 2026

  • Accepted: 12 October 2026

  • Published: 21 October 2026

  • DOI: https://doi.org/10.1038/s41598-026-76024-8