CT基远端尺骨中心定位与偏心度(DUCE)方法在离体标本中的旋转行为及形态学关联
Rotational behaviour and morphological associations of the CT-based distal ulnar centering and eccentricity (DUCE) method in cadaveric specimens
该研究对30只离体上肢进行锥形束CT扫描,评估DUCE方法在下尺桡关节稳定性评估中的表现。结果显示,传统放射尺骨比(RR)随前臂旋转及切迹形态显著变化(P < 0.001),而DUCE中的中心定位和偏心度指标未见此类关联。DUCE提供了基于解剖参考的旋转行为描述,后续临床研究需验证其在病理性不稳定评估中的效用。
- Jan Siad El Barbari1,6,
- Florian Kordon2,
- Holger Kunze3,
- Jonas Armbruster1,
- Paul Alfred Grützner1,
- Sven Yves Vetter1,4,
- Marc Schnetzke5 &
- …
- Benedict James Swartman1
We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.
Abstract
Non-invasive assessment of distal radioulnar joint (DRUJ) stability remains challenging because CT-based measurements, such as the radioulnar ratio (RR), depend on forearm rotation and notch anatomy. The CT-based Distal Ulnar Centering and Eccentricity (DUCE) method describes DRUJ articulation relative to individual notch geometry, separating rotational translation into direction and magnitude. Thirty cadaveric upper limbs underwent cone-beam CT in pronation and supination, 11 also in neutral rotation. Centering (ulnar head centre to a notch-derived reference axis) and Eccentricity (to the deepest notch point) were compared with RR. RR varied with rotation (28.7 ± 8.5% vs. 70.8 ± 13.6%; P < 0.001) and with notch morphology (R2 up to 0.31); no such association was detected for DUCE. Signed Centering reversed systematically (+ 3.11 vs. − 3.10 mm; P < 0.001), while its magnitude remained equivalent. Averaged across both end positions, Centering was equivalent to zero (exploratory ± 0.6 mm equivalence margin; TOST P < 0.001), placing the notch-derived axis at the centre of the rotational arc at group level, though not in individual limbs. Eccentricity did not differ with rotation. Interrater reliability was good to excellent. DUCE provides an anatomically referenced description of rotational DRUJ behaviour. Clinical studies must show whether it improves assessment of pathological instability.
Acknowledgements
We gratefully thank Prof. Friedrich Anderhuber, Macroscopic and Clinical Anatomy, Medical University of Graz, Austria for providing the anatomical specimens.
Funding
Open Access funding enabled and organized by Projekt DEAL. AO Trauma Germany
Author information
Authors and Affiliations
Department for Orthopaedics and Trauma Surgery at Heidelberg University, BG Klinik Ludwigshafen, Ludwig-Guttmann-Str. 13, 67071, Ludwigshafen, Germany
Jan Siad El Barbari, Jonas Armbruster, Paul Alfred Grützner, Sven Yves Vetter & Benedict James Swartman
Pattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
Florian Kordon
Siemens Healthineers AG, Forchheim, Germany
Holger Kunze
Working Group for Intraoperative Imaging and Technology of the DGOU, AGiTEC, Berlin, Germany
Sven Yves Vetter
German Joint Center Heidelberg, ATOS Clinic Heidelberg, Heidelberg, Germany
Marc Schnetzke
Rehaklinik Bellikon, Suva Clinics, Bellikon, Switzerland
Jan Siad El Barbari
Authors
- Jan Siad El Barbari
- Florian Kordon
- Holger Kunze
- Jonas Armbruster
- Paul Alfred Grützner
- Sven Yves Vetter
- Marc Schnetzke
- Benedict James Swartman
Corresponding author
Correspondence to Benedict James Swartman.
Ethics declarations
Competing interests
H.K. and F.K. are employees of Siemens Healthineers AG, Forchheim, Germany. The cone-beam CT device used in this study (Arcadis Orbic) is manufactured by Siemens Healthcare GmbH, Erlangen, Germany. The MINTOS research group has received grants from Siemens Healthineers, Forchheim, Germany. This research received funding from AOTrauma, Germany. Neither Siemens Healthineers nor AOTrauma had any influence on the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The remaining authors declare no competing interests.
Ethical approval
Ethical approval for the use of human cadaveric material was granted by the Ethics Committee of the State Medical Association of Rhineland-Palatinate, Germany (No. 837.299.17). All specimens were obtained through the anatomical body donation programme of the Medical University of Graz.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
El Barbari, J.S., Kordon, F., Kunze, H. et al. Rotational behaviour and morphological associations of the CT-based distal ulnar centering and eccentricity (DUCE) method in cadaveric specimens. Sci Rep (2026). https://doi.org/10.1038/s41598-026-67682-9
Received: 23 March 2026
Accepted: 18 August 2026
Published: 28 October 2026
DOI: https://doi.org/10.1038/s41598-026-67682-9