跳到正文
原文
Nature 健康护理主题·· 18 天前AI 评分37

100 μm 和 160 μm 角膜帽厚度对兔眼 SMILE 手术后角膜形态和生物力学特性的影响

Effects of corneal cap thickness on corneal morphological and biomechanical properties of rabbits in vivo following SMILE

AI 导读

本研究比较了100 μm和160 μm角膜帽厚度对兔眼SMILE手术后角膜形态、内皮细胞密度、生物力学特性和上皮厚度的影响。术后3个月,两种厚度的角膜平坦化程度相当,内皮细胞密度无显著差异。160 μm组在术后早期表现出不同的生物力学和上皮重塑轨迹,但最终角膜形态未见显著差异。

正文

Scientific Reports (2026) Cite this article

We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.

Abstract

To investigate the effects of 100 μm and 160 μm corneal cap thicknesses on corneal morphology, endothelial cell density, biomechanics and epithelial thickness in rabbit eyes after SMILE, and to provide experimental reference for clinical surgical parameter selection. Twenty-four New Zealand white rabbits were randomly allocated to a 100-μm corneal cap group (group A) and a 160-μm group (group B), with 12 rabbits in each group and balanced sex distribution (6 males and 6 females in each group). SMILE was performed on the right eye of all rabbits using a uniform VisuMax program with programmed refractive correction of − 4.00 D, an optical zone of 6.50 mm, a cap diameter of 7.60 mm, and an incision at the 120° position with a 45° angle. Corneal morphology (Pentacam), endothelial cell density (specular microscopy), biomechanical properties (Corvis ST), and epithelial thickness (anterior-segment OCT) were measured preoperatively and at 1 week, 1 month and 3 months postoperatively. Between-group comparisons at each time point were performed with independent-samples t-tests; longitudinal trajectories were analyzed with a two-way mixed-design analysis of variance (group as the between-subjects factor; time and the group × time interaction as within-subjects effects). Multiplicity was controlled using the Benjamini–Hochberg false-discovery-rate procedure for secondary outcomes. Baseline central endothelial cell density was significantly higher in group B than in group A (2994.42 ± 237.96 vs 2693.60 ± 345.72 cells/mm2; P = 0.021); baseline anterior and posterior Km and anterior chamber volume also differed between groups (P < 0.05), reflecting imperfect baseline balance in this small randomized cohort, whereas the remaining baseline indicators were comparable. Both groups demonstrated comparable postoperative corneal flattening, with comparable central endothelial cell density throughout the 3-month follow-up. Early postoperative intergroup differences in corneal asphericity and Corvis ST parameters were observed but were largely nominal after false-discovery-rate adjustment. Group B had lower Def Amp Max and higher SSI at 1 and 3 months (FDR-corrected). The group × time interaction was significant for Def Amp Max, IR, SP-A1, SSI, ARTh, and corneal epithelial thickness, indicating different postoperative remodeling trajectories between the two caps. No significant intergroup differences in corneal morphological parameters were detected at 3 months. In this rabbit SMILE model, both 100-μm and 160-μm caps produced comparable postoperative corneal flattening and no significant reduction in central endothelial cell density over the 3-month follow-up. Cap thickness was associated with different postoperative biomechanical and epithelial remodeling trajectories (significant group × time interactions for Def Amp Max, SSI, and epithelial thickness), without affecting corneal morphological outcomes at the final follow-up.

Acknowledgements

The authors thank the technical staff of the Ophthalmology Laboratory of Jining First People’s Hospital for their support in animal experiments and testing.

Funding

This study was supported by the Shandong Provincial Medical and Health Science and Technology Project: Establishment of an animal model of femtosecond laser deep stromal lenticule extraction and investigation of postoperative outcomes.

Author information

Author notes

  1. These authors contributed equally: Man Wang and Haoge Bai.

Authors and Affiliations

  1. Clinical Medical College, Jining Medical University, Jining, 272000, China

    Man Wang & Haoge Bai

  2. Department of Ophthalmology, Jining First People’s Hospital, Jining, 272011, China

    Mingxia Tian

Authors

  1. Man Wang
  2. Haoge Bai
  3. Mingxia Tian

Corresponding author

Correspondence to Mingxia Tian.

Ethics declarations

Competing interests

The authors declare no competing interests.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wang, M., Bai, H. & Tian, M. Effects of corneal cap thickness on corneal morphological and biomechanical properties of rabbits in vivo following SMILE. Sci Rep (2026). https://doi.org/10.1038/s41598-026-77480-y

Download citation

  • Received: 19 July 2026

  • Accepted: 20 October 2026

  • Published: 02 November 2026

  • DOI: https://doi.org/10.1038/s41598-026-77480-y