Nature 健康护理主题·· 2026-10-09AI 评分26

年龄与自动实时平均(ART)对高分辨率 SD-OCT 视网膜条带可见性的影响

Influence of age and averaging on band visibility in high-resolution optical coherence tomography

AI 导读

一项研究评估年龄与自动实时平均(ART)对高分辨率 SD-OCT 视网膜条带可见性的影响。较高 ART 改善神经纤维层、IPL-3/-4/-5、RPE-1/-5 可见性,RPE 亚带在黄斑上 5° 较中心凹更常检出

正文

Scientific Reports (2026) Cite this article

We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.

Abstract

This study assessed the influence of age on band visibility in spectral-domain optical coherence tomography (SD-OCT) with < 3 μm axial resolution and evaluated intergrader reliability using a custom review tool incorporating 28 retinal bands. Seventy-two eyes of 72 individuals with normal retinas (< 45 years: n = 16; 45–65 years: n = 30; > 65 years: n = 26) were imaged using a prototype SD-OCT device with varying automatic real-time averaging (ART) levels. Scans were acquired through the foveal center (ART 9, 25, 100) and at 5° superior (ART 9). Band visibility was graded using custom software supported by longitudinal reflectivity profiles at nine locations and analyzed using chi-square and regression models. Intergrader reliability varied between larger hyperreflective and thin hyporeflective bands (inner plexiform layers (IPL) 2 and 4; retinal pigment epithelium layers (RPE) 1, 3, 5). Higher ART levels improved visibility of the nerve fiber layer, IPL-3, -4, and − 5, RPE-1, and − 5. RPE sub-bands were more frequently detected at 5° superior than at the fovea. Higher age was associated with reduced visibility of the internal limiting membrane, inner nuclear layer and RPE-5. These findings suggest a modest age-related decline in retinal band visibility under high-resolution conditions, which should be accounted for in clinical trials.

Funding

This work was supported by Heidelberg Engineering GmbH (Heidelberg, Germany).

Author information

Author notes

  1. These authors contributed equally: Lukas Goerdt and Rosa Dolz-Marco.

Authors and Affiliations

  1. Department of Ophthalmology and Visual Sciences, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, AL, 35294-0019, USA

    Lukas Goerdt, Liyan Gao & Christine A. Curcio

  2. Department of Ophthalmology, University of Bonn, Bonn, Germany

    Lukas Goerdt

  3. Unit of Macula, Oftalvist Clinic, Valencia, Spain

    Rosa Dolz-Marco

  4. Department of Computer Science, University of Alabama at Birmingham, Birmingham, AL, USA

    Kenneth R. Sloan

Authors

  1. Lukas Goerdt
  2. Rosa Dolz-Marco
  3. Kenneth R. Sloan
  4. Liyan Gao
  5. Christine A. Curcio

Corresponding author

Correspondence to Christine A. Curcio.

Ethics declarations

Competing interests

CAC receives research funds from Heidelberg Engineering and Genentech/ Hoffman LaRoche and consults for Astellas, Boehringer Ingelheim, Osanni, Annexon, Mobius, Ripple, Sparing Vision, Octant, Sanofi, Espansione, Merck, Ikarovec, and Topcon (outside this project). LG received honoraria from Novartis Pharma AG and Bayer Healthcare AG and consults for BioEQ/Formycon (outside this project). RDM, LGao, KRS do not have competing interests.This work was supported by Heidelberg Engineering GmbH (Heidelberg, Germany).

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Goerdt, L., Dolz-Marco, R., Sloan, K.R. et al. Influence of age and averaging on band visibility in high-resolution optical coherence tomography. Sci Rep (2026). https://doi.org/10.1038/s41598-026-73321-0

Download citation

  • Received: 31 May 2026

  • Accepted: 22 September 2026

  • Published: 09 October 2026