Nature 健康护理主题·· 2026-10-15AI 评分45

机械通气成人患者早期深至浅镇静与持续浅或清醒策略的目标试验模拟

Early deep-to-light sedation versus a sustained light-or-awake strategy in mechanically ventilated adults: a target trial emulation

AI 导读

基于MIMIC-IV数据库的目标试验模拟显示,早期深至浅镇静与持续浅或清醒策略在28天无呼吸机天数上无显著差异(加权均值差 -0.04 天,95% CI -1.32至1.29),且拔管率无统计学差异(HR 0.97,95% CI 0.84–1.11)。敏感性分析提示深至浅镇静组无呼吸机天数较少,但研究未发现该策略带来确切获益。

正文

Scientific Reports (2026) Cite this article

We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.

Abstract

Observational studies comparing sedation depth strategies in mechanically ventilated patients have relied on observed consciousness levels alone to define exposure, potentially conflating intentional drug-induced sedation with low arousal caused by residual medications, other agents, or underlying illness. We applied the target trial emulation framework with the clone-censor-weight method to compare early deep-to-light sedation (DTLS) versus a sustained light-or-awake strategy, using a joint exposure definition that requires both Richmond Agitation-Sedation Scale (RASS) depth and qualifying continuous sedative infusion. Using MIMIC-IV (2008–2022), we identified 5,086 adults receiving invasive mechanical ventilation for ≥ 48 h. Each patient was cloned to both strategies. During the primary 144-hour adherence window, inverse probability weights accounted for measured predictors of artificial censoring. The primary outcome was 28-day ventilator-free days (VFDs); successful extubation was analysed with death as a competing event. VFD outcomes were observed before artificial censoring in 1,481 sustained-light-or-awake and 622 DTLS clones. Weighted mean VFDs were 17.72 days for DTLS versus 17.76 days for sustained light-or-awake, a difference of − 0.04 days (95% CI, − 1.32–1.29). The cause-specific extubation HR was 0.97 (95% CI, 0.84–1.11). A sensitivity cohort without future minimum ventilation or ICU-duration requirements (n = 15,842) showed fewer VFDs with DTLS (difference, − 1.03 days; 95% CI, − 1.47 to − 0.61). These findings do not establish a DTLS benefit; duration-based selection, residual confounding, and limited late-window support constrain interpretation.

Acknowledgements

The authors thank the MIT Laboratory for Computational Physiology and the Beth Israel Deaconess Medical Center for maintaining and providing access to the MIMIC-IV database through PhysioNet. We also thank Professor Shu Shiyu for methodological guidance during the study design phase.

Funding

This study received no specific funding.

Author information

Authors and Affiliations

  1. Department of Anesthesiology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, China

    Yuhang Zhang & Xiaosu Liu

  2. Department of Critical Care Medicine, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, 400010, China

    Menglin Han

  3. Department of Anesthesiology, Zigong Fourth People’s Hospital, Zigong, 643000, Sichuan, China

    Guanyu Chen & Lulu Zhang

Authors

  1. Yuhang Zhang
  2. Menglin Han
  3. Xiaosu Liu
  4. Guanyu Chen
  5. Lulu Zhang

Corresponding author

Correspondence to Lulu Zhang.

Ethics declarations

Competing interests

The authors declare no competing interests.

Ethical approval

The MIMIC-IV database is a de-identified, publicly available dataset approved for research use by the institutional review board of the Massachusetts Institute of Technology (MIT) and Beth Israel Deaconess Medical Center (BIDMC). Access was granted through PhysioNet credentialed data use agreement (certification number: 13312797). Individual patient consent was waived owing to the de-identified nature of the data. The study was conducted in accordance with the Declaration of Helsinki.

Consent for publication

Not applicable.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhang, Y., Han, M., Liu, X. et al. Early deep-to-light sedation versus a sustained light-or-awake strategy in mechanically ventilated adults: a target trial emulation. Sci Rep (2026). https://doi.org/10.1038/s41598-026-75074-2

Download citation

  • Received: 18 April 2026

  • Accepted: 05 October 2026

  • Published: 15 October 2026

  • DOI: https://doi.org/10.1038/s41598-026-75074-2

来源:Nature 健康护理主题 · nature.com