无触点非粘合3件式人工晶状体无囊袋固定新术式长期疗效分析
Long-term outcomes of a novel non-haptic exposure technique for sutureless, glueless intrascleral fixation of a 3-piece intraocular lens: a single surgeon series of 553 eyes
一项针对553只眼的研究显示,使用无触点非粘合3件式人工晶状体无囊袋固定的新术式,术后视力显著改善,最终最佳矫正视力从0.60降至0.20 logMAR(p=0.002),77%的眼最终视力达到0.48 logMAR或更好。主要并发症发生率较低,未见人工晶状体脱位和巩膜侵蚀。
- Article
- Published: 16 November 2026
Cataract
Eye (2026) Cite this article
Abstract
Background/Objectives
To evaluate the long-term outcomes of a novel non-haptic exposure technique for sutureless, glueless intrascleral fixation of a 3-piece intraocular lens (IOL) in eyes with inadequate capsular support.
Subjects/Methods
This study included 553 eyes of 524 consecutive patients who underwent the non-haptic exposure technique for sutureless, glueless intrascleral fixation of a 3-piece IOL between June 2017 and June 2025. Eyes with active inflammation, uncontrolled glaucoma, severe corneal opacity, or follow up of less than 6 months were excluded. The primary outcome was final best corrected visual acuity (BCVA). Secondary outcomes included uncorrected visual acuity (UCVA) and postoperative complications. Subgroup analysis compared surgical aphakia following cataract surgery (Group A) with other secondary aetiologies (Group B).
Results
Mean BCVA improved from 0.60 to 0.20 logMAR (p = 0.002). Mean UCVA improved from 1.47 (SD 0.64) to 0.35 (SD 0.36) logMAR (p < 0.001), with 77% of eyes achieving a final visual acuity of 0.48 logMAR or better. Late postoperative complications included cystoid macular oedema (6.7%), retinal detachment (2.9%), and IOL subluxation (2.2%). Retinal detachment occurred more frequently in Group B than in Group A (p = 0.039). No eye developed haptic extrusion, scleral erosion, or acute endophthalmitis during follow up.
Conclusions
The non-haptic exposure technique for sutureless, glueless intrascleral fixation of a 3-piece IOL provided favourable long-term visual outcomes with a low incidence of postoperative complications in eyes with inadequate capsular support. The absence of haptic extrusion and scleral erosion throughout follow up supports the long-term stability of this technique.
This is a preview of subscription content, access via your institution
Access options
Access through your institution
Subscribe to this journal
Receive 18 print issues and online access
251.40 € per year only 13.97 € per issue
Buy this article
- Purchase on SpringerLink
- Instant access to the full article PDF.
39,95 €
Prices may be subject to local taxes which are calculated during checkout
Additional access options:
Data availability
The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.
References
Chen SP, Chang DF. Secondary IOL implantation without capsular support. Am J Ophthalmol. 2025;280:230–7. https://doi.org/10.1016/j.ajo.2025.08.023.
Forlini M, Bedi R. Intraocular lens implantation in the absence of capsular support: scleral-fixated vs retropupillary iris-claw intraocular lenses. J Cataract Refract Surg. 2021;47:792–801. https://doi.org/10.1097/j.jcrs.0000000000000529.
Negretti GS, Chan WO, Muqit MMK. Artisan iris-claw intraocular lens implantation in vitrectomised eyes. Eye (Lond). 2021;35:1393–7. https://doi.org/10.1038/s41433-020-1022-x.
Agarwal A, Kumar DA, Jacob S, Baid C, Agarwal A, Srinivasan S. Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules. J Cataract Refract Surg. 2008;34:1433–8. https://doi.org/10.1016/j.jcrs.2008.04.040.
Kumar DA, Agarwal A. Glued intraocular lens: a major review on surgical technique and results. Curr Opin Ophthalmol. 2013;24:21–9. https://doi.org/10.1097/ICU.0b013e32835a939f.
Gajula S, Manayath GJ, Verghese S, Saravanan VR, Narendran K, Narendran V. Real world outcomes of sutureless and glueless sclerally fixated intraocular lens implantation. Eye (Lond). 2022;36:2334–40. https://doi.org/10.1038/s41433-021-01880-9.
Botsford BW, Williams AM, Conner IP, Martel JN, Eller AW. Scleral fixation of intraocular lenses with gore-tex suture: refractive outcomes and comparison of lens power formulas. Ophthalmol Retin. 2019;3:468–72. https://doi.org/10.1016/j.oret.2019.02.005.
Khan MA, Gupta OP, Smith RG, Ayres BD, Raber IM, Bailey RS, et al. Scleral fixation of intraocular lenses using Gore-Tex suture: clinical outcomes and safety profile. Br J Ophthalmol. 2016;100:638–43. https://doi.org/10.1136/bjophthalmol-2015-306839.
Yu T, Yu M, Wu W, Wu X, Xiao S, Mao J, et al. Outcomes and complications of sutured scleral-fixated foldable intraocular lens implantation: a retrospective study of 5-year follow-up. J Ophthalmol. 2021;2021:5525064. https://doi.org/10.1155/2021/5525064.
Narang P, Narang S. Glue-assisted intrascleral fixation of posterior chamber intraocular lens. Indian J Ophthalmol. 2013;61:163–7. https://doi.org/10.4103/0301-4738.112160.
Beiko G, Steinert R. Modification of externalized haptic support of glued intraocular lens technique. J Cataract Refract Surg. 2013;39:323–5. https://doi.org/10.1016/j.jcrs.2013.01.017.
Yamane S, Inoue M, Arakawa A, Kadonosono K. Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection. Ophthalmology. 2014;121:61–66. https://doi.org/10.1016/j.ophtha.2013.08.043.
Yamane S, Ito A. Flanged fixation: Yamane technique and its application. Curr Opin Ophthalmol. 2021;32:19–24. https://doi.org/10.1097/ICU.0000000000000720.
Baskaran P, Ganne P, Bhandari S, Ramakrishnan S, Venkatesh R, Gireesh P. Extraocular needle- guided haptic insertion technique of scleral fixation intraocular lens surgeries (X-NIT). Indian J Ophthalmol. 2017;65:747–50. https://doi.org/10.4103/ijo.IJO_296_17.
Markan A, Tripathi M, Chhabra S, Rana V. 27-gauge microincision vitrectomy surgery-assisted scleral fixation of intraocular lens: an anterior segment optical coherence tomography-guided study. Indian J Ophthalmol. 2025;73:1653–7. https://doi.org/10.4103/IJO.IJO_1102_25.
Gabor SG, Pavlidis MM. Sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg. 2007;33:1851–4. https://doi.org/10.1016/j.jcrs.2007.07.013.
Wilgucki JD, Wheatley HM, Feiner L, Ferrone MV, Prenner JL. One-year outcomes of eyes treated with a sutureless scleral fixation technique for intraocular lens placement or rescue. Retina. 2015;35:1036–40. https://doi.org/10.1097/IAE.0000000000000431.
Ishikawa H, Uchida K, Terasaki H, Sakamoto T, Kakinoki M, Ohji M, et al. Cystoid macular oedema after flanged intraocular lens scleral fixation using the Yamane technique: a multicentre cohort study. Sci Rep. 2025;15:811. https://doi.org/10.1038/s41598-025-85370-y.
Sutphin JE, Chodosh J, Dana MR. External Disease and Cornea: Section 8, Basic and Clinical Science Course. 2015–6 ed San Francisco, CA: American Academy of Ophthalmology; 2007: 386.
Suren E, Kalayci M, Cetinkaya E, Kucuk MF, Dogan ME, Durmaz D, et al. Evaluation of the findings of patients who underwent sutureless flanged transconjunctival intrascleral intraocular lens implantation with or without pars plana vitrectomy. J Ophthalmol. 2021;2021:4617583. https://doi.org/10.1155/2021/4617583.
Acknowledgements
Nil
Funding
None.
Author information
Authors and Affiliations
Department of Ophthalmology, Sohana Multi-superspecilaty Hospital, Mohali, Punjab, India
Pawan Puneet Malhotra, Amanpreet Kaur & Gurmeet Singh Mangat
Department of Ophthalmology, INHS Asvini, Mumbai, India
Vipin Rana
Sadguru Netra Chikitsalaya, Chitrakoot, Madhya Pradesh, India
Alok Sen & Ritika Chauhan
Authors
- Pawan Puneet Malhotra
- Vipin Rana
- Alok Sen
- Ritika Chauhan
- Amanpreet Kaur
- Gurmeet Singh Mangat
Contributions
Conception and design: PPM, AK, Data collection: PPM AK, AS, RC, GSM, Analysis and interpretation: PPM, AK, VR, AS, RC, GSM.
Corresponding author
Correspondence to Pawan Puneet Malhotra.
Ethics declarations
Competing interests
The authors of the study declare that no conflict of interest exists in the compilation, theme and subsequent publication of this professional communication, and that it is not supported by any pharmaceutical company.
Disclosure(s)
This technique was previously presented by Dr. Pawan Puneet Malhotra as an educational surgical video on the American Academy of Ophthalmology platform in January 2024 and was recognised among the platform’s most viewed surgical videos of the year.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Manuscript has been read and approved by all the authors, that the requirements for authorship as stated earlier in this document have been met, and that each author believes that the manuscript represents honest work. This is our original work and has not been submitted to any other journal
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Malhotra, P.P., Rana, V., Sen, A. et al. Long-term outcomes of a novel non-haptic exposure technique for sutureless, glueless intrascleral fixation of a 3-piece intraocular lens: a single surgeon series of 553 eyes. Eye (2026). https://doi.org/10.1038/s41433-026-05046-3
Received: 28 June 2026
Revised: 07 October 2026
Accepted: 29 October 2026
Published: 16 November 2026
Version of record: 16 November 2026
DOI: https://doi.org/10.1038/s41433-026-05046-3
来源:Nature 健康护理主题 · nature.com