约翰霍普金斯APL研发OsteoSEE超声平台,测试中检出0.5毫米以下应力性骨折
Ultrasonic technology enables earlier stress-fracture detection
约翰霍普金斯应用物理实验室(APL)正在研发超声平台OsteoSEE,利用沿骨表面的声表面波识别皮质骨微结构变化与早期应力性骨折,无需电离辐射。该技术在测试中检出小于0.5毫米的骨折,并获2026年R&D 100奖。团队表示其可能用于军事训练、运动医学与儿科等场景,并正探索与低强度脉冲超声(LIPUS)结合的可能。
Tibial stress fractures are among the most common overuse injuries affecting military personnel, but they can be difficult to identify in their earliest stages. Small stresses in the bone may develop before an injury becomes apparent through conventional diagnostic tools, creating a window of opportunity for earlier detection to enable intervention.
Researchers at the Johns Hopkins Applied Physics Laboratory (APL) in Laurel, Maryland, are developing Osteo Surface Echo Evaluation (OsteoSEE), a noninvasive, ultrasound-based platform that uses surface acoustic waves to identify microstructural changes and early-stage fractures in cortical bone—the dense outer layer of bone—avoiding the use of ionizing radiation. The technology was named a 2026 R&D 100 Award winner, recognizing its innovative approach to early fracture detection.
"One of the most compelling applications is supporting military readiness," said Anna Knight, OsteoSEE principal investigator and a senior biomechanical engineer at APL. "Fully developed stress fractures can be disabling to individual warfighters, and the prevalence of this overuse injury limits mission readiness across the force."
Riding the wave
Conventional X-ray imaging can lack sensitivity to early-stage or hairline stress fractures, while advanced imaging such as MRI is more costly and requires access to specialized facilities. To address these limiting factors, OsteoSEE uses commercial off-the-shelf (COTS) ultrasound transducers to direct sound waves toward the bone at precise angles and frequencies. Rather than sending most of that energy through the middle layer of the bone, the system generates surface acoustic waves that travel along its outer layer.
Because these waves move more slowly and do not attenuate as fast along the bone surface, they are sensitive to very small changes. OsteoSEE measures how the waves change as they pass across the area being examined, looking for patterns that may indicate accumulating damage or a developing fracture.
"Using commercially available components and real-time analysis will make fracture assessment more practical in training or operational settings, where timely information can make a difference," said Austin Veith, a biomedical engineer at APL and another member of the research team.
In testing, OsteoSEE has detected fractures smaller than 0.5 millimeters—thinner than a standard credit card—and below the stated resolution of conventional planar X-ray imaging. The team has also verified that those signals correspond to actual structural changes in the bone. The injury model used to develop and test OsteoSEE was verified against micro-CT imaging, providing an independent way to confirm the beginnings of fracture damage.
"OsteoSEE reflects the value of leveraging deep technical expertise from across APL to develop innovative solutions that enhance military performance. In this case, we're combining our expertise in military injury biomechanics, advanced acoustics, and complex signals processing competencies to formulate a novel way to assess bone health," said Joan Hoffmann, mission area executive for Research and Exploratory Development at APL.
"By investing in early exploratory research to verify the feasibility of our approach, and supporting the work through multiple stages of development, we've been able to establish a promising research concept and continue advancing it toward a capability with meaningful potential for the warfighter."
From detection toward prevention and healing
The team is also exploring what could come after detection. OsteoSEE has been designed for potential compatibility with low-intensity pulsed ultrasound (LIPUS), which has been studied for supporting bone healing. Future research could examine whether sensing and therapeutic ultrasound capabilities could be combined.
The technology could also have applications beyond military medicine, including sports medicine and pediatric care, where a nonionizing approach could provide a safer alternative in assessing certain bone injuries.
Key medical concepts
Clinical categories
Who's behind this story?
Lisa Lock
BA art history, MA material culture. Former museum editor, paramedic, and transplant coordinator. Editing for Science X since 2021. Full profile →
Andrew Zinin
Master's in physics with research experience. Long-time science news enthusiast. Plays key role in Science X's editorial success. Full profile →
Citation: Ultrasonic technology enables earlier stress-fracture detection (2026, October 24) retrieved 24 October 2026 from https://medicalxpress.com/news/2026-10-ultrasonic-technology-enables-earlier-stress.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.
来源:Medical Xpress · medicalxpress.com