东京大学团队开发磁控胶囊:在猪肠模型中验证小肠表面采样可行性
Magnetically controlled capsule shows promise for investigating hard-to-reach regions of the small intestine
东京大学研究团队在期刊 Device 发表研究,展示了一种通过外部磁体控制内部刷头采集小肠样本的胶囊原型。该装置在离体猪小肠实验中成功操作,采集的样本适用于 16S rRNA 基因测序。目前该设备仍处于早期开发阶段,尚未进行人体临床验证。
A small capsule could change how we study the microbiome of the small intestine. A team led by researchers at the University of Tokyo has created a pill-shaped device designed to take samples from the small intestine using a tiny extendable brush.
Although the device is still in the early stages of development, they have demonstrated that it could be magnetically controlled to move through extracted pig intestines and sweep useful samples from the intestinal surface. In the future, this type of device could provide a more comfortable and complementary option to current endoscopic procedures.
Beyond the reach of routine scopes
Endoscopes are indispensable when doctors need to examine the gastrointestinal (GI) tract, whether it's to take photos, collect samples or provide treatments such as removing polyps. Typical scopes go either from the mouth to the beginning of the small intestine (an upper endoscopy) or through the large intestine (a colonoscopy). Exploring much of the long and narrow small intestine is considerably more challenging.
One examination method is capsule endoscopy. The patient swallows a disposable pill containing a camera that sends images to an external recorder as it passes through their GI system. While capsule endoscopy is very helpful for diagnosing and monitoring some conditions, commercially available capsules are mainly designed for imaging and do not routinely collect samples.
Now, a team at the University of Tokyo has tested a prototype for a new type of controllable capsule designed to take samples from the surface of the small intestine. The paper is published in the journal Device.
"In this early-stage study, we have demonstrated a capsule that can actively collect useful biological samples from the intestinal surface using a magnetically controlled retractable brush," said postdoctoral researcher Yuguo Dai from the Graduate School of Engineering at the University of Tokyo. "The collected samples were suitable for 16S rRNA gene sequencing, a method commonly used for microbiome analysis."
Magnetic control steers the sampling brush
The capsule is a compact device that encases a flexible brush, a screw mechanism and magnets. The team tested the capsule in the lab on small intestines extracted from pigs.
Two robotic arms with external magnets were used to control the internal magnets in the capsule without making contact. One stabilized the capsule near the target area, and the other operated its internal screw to extend a brush, sweep up a sample and retract it inside for safekeeping.
"We see this technology as a potential complement to existing clinical sampling methods, particularly for patients who need sampling from difficult-to-access regions or who may benefit from a less invasive and less uncomfortable procedure," said Dai.
As patient comfort is a main concern, further miniaturization of the capsule will be necessary to reduce any issues with ingestion or any hindrance to the capsule moving smoothly through the GI system.
Extending magnetic reach before clinical testing
Another challenge is the limited operating distance of the magnets. In tests, the external magnets were positioned close to the intestine, but for this to work with the shape of the human body, the distance would need to be greatly extended.
"For now, our initial results are encouraging and we are happy to be able to demonstrate that the basic concept is feasible. Our next steps are to overcome the challenges of size, operating distance and ensuring that collected samples are protected," said Dai.
"In the future, if the capsule can eventually be clinically validated, this approach could complement other endoscopic procedures, potentially offer a more comfortable approach to intestinal sampling and possibly help reveal how microbial communities vary at different locations within the human intestine. This could provide us with new information for studying the diversity of the intestinal environment and how it relates to our health."
Publication details
Yuguo Dai et al, Magnetically actuated brush-structured capsule for intestinal surface sampling, Device (2026). DOI: 10.1016/j.device.2026.101304
Journal information: Device
Key medical concepts
Who's behind this story?
Sadie Harley
BSc Life Sciences & Ecology. Microbiology lab background with pharmaceutical news experience in oil, gas, and renewable industries. Full profile →
Robert Egan
Bachelor's in mathematical biology, Master's in creative writing. Well-traveled with unique perspectives on science and language. Full profile →
Citation: Magnetically controlled capsule shows promise for investigating hard-to-reach regions of the small intestine (2026, October 2) retrieved 2 October 2026 from https://medicalxpress.com/news/2026-10-magnetically-capsule-hard-regions-small.html
This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no part may be reproduced without the written permission. The content is provided for information purposes only.
来源:Medical Xpress · medicalxpress.com