Abstract
Sleep staging is essential for evaluating sleep quality, yet conventional polysomnography is costly, intrusive, and difficult to deploy in everyday settings. This study presents an HRV-centered sleep-staging framework for ECG-derived RR intervals and smartwatch PPG-derived IBI sequences. Rather than introducing a new Transformer architecture, the study systematically evaluates multi-window HRV representation and sleep-progress context for four-class sleep staging, while examining demographic information and feature-interaction strategies as auxiliary components. The framework extracts time-domain, frequency-domain, and nonlinear HRV features from multiple temporal windows, combines them primarily with sleep-progress context while optionally incorporating demographic context, and uses a lightweight Transformer encoder as a temporal integration module for classifying Wake, Light sleep, Deep sleep, and REM sleep. In the final baseline comparison, the proposed configuration achieved accuracies and Cohen’s Kappa coefficients of 0.6988/0.5326 on the SHHS 1000 subset, 0.6958/0.4830 on Huami ECG, and 0.6915/0.4615 in the Huami smartwatch PPG setting. Ablation analyses showed that multi-window HRV representation and temporal sleep-progress information provided the most consistent contributions, whereas demographic variables and feature-interaction strategies had auxiliary and dataset-dependent effects. For practical interpretation, configurations without the future-context 300-s feature are considered the relevant setting because they exclude explicitly post-epoch information, whereas configurations containing this feature are treated only as offline retrospective analyses. Further validation across independent datasets, wearable devices, prospective deployment settings, and external PPG interval-estimation pipelines is needed before broader real-world use.
Acknowledgements
The authors gratefully acknowledge the valuable support and constructive feedback received from colleagues and reviewers, which greatly contributed to the completion of this work.
Funding
Yimin Wang discloses support for the research of this work from the Research Fund of Macao University of Science and Technology (FRG-MUST; grant no. FRG-25-038-FA), the Major Project of the National Social Science Foundation of China (grant no. 24&ZD206), and the 2024 Guangdong Provincial Social Science Planning Co-construction Project (grant no. GD24XXYS012).
Author information
Authors and Affiliations
Faculty of Humanities and Arts, Macau University of Science and Technology, Avenida WaiLong, Macau SAR, Macau, 999078, China
Yimin Wang, Jiaqi Li, Yu Zou & Zhangyan Yan
Faculty of Innovation Engineering, Macau University of Science and Technology, Avenida WaiLong, Macau SAR, Macau, 999078, China
Yiran Peng
School of Information and Communication Engineering, Communication University of China, No. 1 Dingfuzhuang East Street, Chaoyang District, Beijing, 100024, China
Ziyue Zhang, Chenxi Cao, Yujiao Chai, Zixiang Cai & Zhulin Tao
Authors
- Yimin Wang
- Yiran Peng
- Jiaqi Li
- Ziyue Zhang
- Chenxi Cao
- Yujiao Chai
- Zixiang Cai
- Yu Zou
- Zhangyan Yan
- Zhulin Tao
Corresponding author
Correspondence to Zhangyan Yan.
Ethics declarations
Competing interests
The authors declare no competing interests.
Ethical approval and informed consent statements
The study protocol was reviewed and approved by the Research Ethics Committee of the Faculty of Humanities and Arts at Macau University of Science and Technology (Approval No. MUST-FA-2025021), and all procedures adhered to applicable institutional and regulatory requirements. This study involves secondary analysis of two previously collected, de-identified datasets: the Sleep Heart Health Study (SHHS) and the Huami Sleep Dataset. The present study used de-identified secondary data from the Huami Sleep Dataset. No direct participant interaction was involved in the present analysis. The requirement for additional informed consent for the secondary analysis of the SHHS and Huami datasets was waived by the Research Ethics Committee of the Faculty of Humanities and Arts at Macau University of Science and Technology.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Wang, Y., Peng, Y., Li, J. et al. Multi-window HRV and temporal context for sleep staging from ECG and smartwatch PPG-derived intervals. Sci Rep (2026). https://doi.org/10.1038/s41598-026-73376-z
Received: 22 January 2026
Accepted: 22 September 2026
Published: 05 November 2026
DOI: https://doi.org/10.1038/s41598-026-73376-z
Keywords
来源:Nature 健康护理主题 · nature.com