打印角度对3单位即刻固定牙科修复体适配度的影响

Effect of printing angulation on the fit of additively manufactured provisional three-unit fixed dental prostheses

AI 导读

一项体外研究评估了9种不同打印角度的3单位即刻固定牙科修复体,发现不同角度对不同区域的边缘、颈缘、轴面、轴-咬合和咬合间隙有显著影响。0°近远中角度与150°/180°颊舌向角度组合在边缘和咬合间隙上表现较好,但轴面间隙最小出现在210°/0°组合。这些结果描述了测试的角度配置,但未确定通用最优配置或临床表现。

正文

Scientific Reports (2026) Cite this article

We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.

Abstract

Printing orientation may influence the fit of additively manufactured provisional fixed dental prostheses (FDPs). This in vitro study evaluated 108 three-unit FDPs fabricated with a liquid crystal display-based masked stereolithography printer at nine combinations of buccolingual (150°, 180°, 210°) and mesiodistal (0°, 15°, 45°) angulations, with 12 FDPs per combination. Marginal, cervical, axial, axio-occlusal, and occlusal gaps were assessed by silicone replicas seated on a cobalt–chromium master model under finger pressure. Regional means from 28 measurements per abutment underwent separate unequal-variance factorial analyses with Holm adjustment. Buccolingual effects were detected for all regions; mesiodistal effects were detected for all regions except the premolar axial gap. At 0° mesiodistal angulation, the marginal-gap difference between 150° and 180° buccolingual orientations was 624.38 μm (95% confidence interval 470.87–777.88) for premolars and 442.02 μm (323.73–560.31) for molars. The 180°/0° and 180°/15° combinations generally had lower marginal and occlusal means, but the smallest axial means occurred at 210°/0°. These findings describe the tested orientation and support configurations; they do not establish a universal optimum or clinical performance.

Acknowledgements

None.

Funding

This study received no external funding.

Author information

Authors and Affiliations

  1. Dental Research Center, Dentistry Research Institute, Prosthodontic Department, Tehran University of Medical Sciences, Tehran, Iran

    Mahnaz Arshad

  2. Department of Prosthodontics, Tehran University of Medical Sciences, Tehran, Iran

    Mahya Hasanzade

  3. Student Research Committee, Tehran University of Medical Sciences, International Campus, Tehran, Iran

    Zaid Almsaadi

  4. Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India

    Seyed Ali Mosaddad

  5. Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, Madrid, Spain

    Seyed Ali Mosaddad

Authors

  1. Mahnaz Arshad
  2. Mahya Hasanzade
  3. Zaid Almsaadi
  4. Seyed Ali Mosaddad

Corresponding author

Correspondence to Seyed Ali Mosaddad.

Ethics declarations

Competing interests

The authors declare no competing interests.

Consent for publication

Not applicable.

Use of artificial intelligence

ChatGPT (OpenAI) assisted with statistical code development, visualization code, and language revision. The authors retain responsibility for the scientific content and interpretation.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Arshad, M., Hasanzade, M., Almsaadi, Z. et al. Effect of printing angulation on the fit of additively manufactured provisional three-unit fixed dental prostheses. Sci Rep (2026). https://doi.org/10.1038/s41598-026-80022-1

Download citation

  • Received: 02 September 2026

  • Accepted: 04 November 2026

  • Published: 06 November 2026

  • DOI: https://doi.org/10.1038/s41598-026-80022-1