基于单平面移动透视的个人化2D/3D图像配准流程用于膝关节自动配准

A personalized 2D/3D image registration pipeline for automated knee registration using single-plane moving fluoroscopy

AI 导读

该研究提出一种用于单平面移动透视膝关节图像自动配准的个人化2D/3D图像配准流程。在自然膝关节和植入物数据集中,结合基于学习的姿态估计与可微渲染细化,梯度细化后95%以上的测试帧满足股骨与胫骨内平面平移误差<1 mm且几何旋转误差<1°的成功标准。

正文

Scientific Reports (2026) Cite this article

We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.

Abstract

Accurate knee joint kinematics are essential for biomechanical research and clinical assessment. Single-plane fluoroscopy is one of the most accurate tools for measuring in vivo joint motion, but manual estimation of three-dimensional bone pose from individual fluoroscopic frames remains labor-intensive and time-consuming. In this study, we present a personalized 2D/3D image registration pipeline for automated registration of knee fluoroscopic images acquired using single-plane moving fluoroscopy. The proposed framework combines pose standardization across acquisition sessions, subject-specific learning-based pose estimation, and differentiable-rendering-based pose refinement. Tested using fluoroscopic datasets of both natural knees and knee implants together with a PyTorch3D-based differentiable renderer, we trained subject-specific pose estimation networks for both anatomy types. Evaluation against manually matched reference poses showed mean initial in-plane translation differences of approximately 1.1–2.1 mm and geodesic rotation differences of 1.3–3.6\(^\circ\) with mask-only input, while out-of-plane translation differences remained larger, as expected in single-plane imaging. Gradient-based refinement using gradient correlation coefficient (GCC) further reduced the disagreement with the manual reference poses, resulting in sub-millimetre in-plane translation differences and sub-degree rotational differences, with over 95% of test frames satisfying the predefined success criterion that both the femoral and tibial registrations had absolute in-plane translation differences below 1 mm in both \(T_x\) and \(T_y\) and a geodesic rotation difference below 1\(^\circ\). These results quantify agreement with the existing manual registration workflow rather than independently validated anatomical pose accuracy.

Similar content being viewed by others

Acknowledgements

The authors thank Dr. Barbara Postolka and Dr. Renate List for their contributions to the development of the single-plane fluoroscopic tracking workflow and manual matching.

Funding

Open access funding provided by Swiss Federal Institute of Technology Zurich. This work was supported by the China Scholarship Council through a CSC Scholarship awarded to J.W.

Author information

Authors and Affiliations

  1. Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland

    Jinhao Wang, Saša Ćuković, Florian Vogl & William R. Taylor

  2. School of Biomedical Engineering, Shanghai, China

    Xia Li

Authors

  1. Jinhao Wang
  2. Xia Li
  3. Saša Ćuković
  4. Florian Vogl
  5. William R. Taylor

Corresponding author

Correspondence to William R. Taylor.

Ethics declarations

Competing interests

The authors declare no competing interests.

Ethics statement

This study was a secondary analysis of previously collected fluoroscopic and anatomical-model data. The original data-acquisition protocols were approved by the Ethics Committee of the Canton of Zurich (KEK-ZH-Nr. 2016-00410), the ETH Zurich Ethics Commission (EK 2013-N-90), and the Ethics Committee of Charité–Universitätsmedizin Berlin (EA4/069/06), as reported in the original cohort studies1,26. All methods were carried out in accordance with relevant guidelines and regulations and the Declaration of Helsinki. Written informed consent was obtained from all participants at the time of the original data acquisition. No new participants were recruited and no new participant data were acquired for the present study.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wang, J., Li, X., Ćuković, S. et al. A personalized 2D/3D image registration pipeline for automated knee registration using single-plane moving fluoroscopy. Sci Rep (2026). https://doi.org/10.1038/s41598-026-73343-8

Download citation

  • Received: 26 May 2026

  • Accepted: 22 September 2026

  • Published: 01 October 2026

  • DOI: https://doi.org/10.1038/s41598-026-73343-8

来源:Nature 健康护理主题 · nature.com