虚拟现实与桌面式自动化视野测定在疑似及确诊青光眼儿童中的比较
Automated perimetry in children with suspected and known glaucoma: virtual reality versus tabletop
一项针对60例青光眼儿童的前瞻性研究显示,Humphrey视觉场(HVF)等效虚拟现实视野(VRF)与标准自动化视野测定(SAP)呈中度相关,MD(P<0.001)和PSD(P<0.001)关联显著,但平均MD、PSD及中心凹敏感度三者间均存在显著差异。
- Article
- Open access
- Published: 18 November 2026
- Stephanie M. Tillit1 na1,
- Nikita Piryani1 na1,
- Jeffrey Liu1,
- Zara Saleem1,
- Mays A. El-Dairi1,
- Bo Wang1,2 &
- …
- Sharon F. Freedman1
Scientific Reports (2026) Cite this article
We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.
Abstract
Humphrey visual field (HVF)-equivalent virtual reality fields (VRFs) have shown promise in adult glaucoma. Research comparing HVF-equivalent VRF to standard automated perimetry (SAP) in pediatric glaucoma is limited. We aimed to evaluate association and agreement between HVF-equivalent VRF and SAP for children with glaucoma. This prospective study enrolled children with known or suspected glaucoma. Participants completed HVF, then VisuALL HVF-equivalent VRF at one visit. A masked ophthalmologist graded visual fields for defects and location. Global parameters were compared between devices. A point-by-point deviation plot analysis was performed. A total of 60 patients (116 eyes) were included, mean age 13.1 ± 2.93 years. Mean retinal nerve fiber layer thickness was 86.1 ± 21.20 μm. Average mean deviation (MD), pattern standard deviation (PSD), and foveal sensitivity significantly differed for HVF versus VRF. There was moderate association between HVF and VRF for MD (P < 0.001) and PSD (P < 0.001). Concordance by region for any defect was 76.2%; point-by-point match rate for total deviation plots was 75.8%. Test duration was longer for HVF versus VRF (4.17 ± 1.19 vs. 2.10 ± 0.18 min, respectively, P < 0.001). Most children (43/44, 97.7%) preferred VRF over HVF. HVF and HVF-equivalent VRF testing modalities yielded moderate association. HVF-equivalent VRF offers a shorter test that children preferred and may supplement SAP.
Funding
BW has research funding from Knights Templar. NP, JL, and ZS (current or former research coordinators) are or were supported through funding from Saving Kids’ Sight Foundation and the Lions Eye Foundation.
Author information
Author notes
These authors contributed equally: Stephanie M. Tillit and Nikita Piryani.
Authors and Affiliations
Department of Ophthalmology, Duke University Medical Center, 2351 Erwin Road, Durham, NC, 27705, USA
Stephanie M. Tillit, Nikita Piryani, Jeffrey Liu, Zara Saleem, Mays A. El-Dairi, Bo Wang & Sharon F. Freedman
Department of Ophthalmology, Wilmer Eye Institute, Johns Hopkins Medicine, Baltimore, MD, USA
Bo Wang
Authors
- Stephanie M. Tillit
- Nikita Piryani
- Jeffrey Liu
- Zara Saleem
- Mays A. El-Dairi
- Bo Wang
- Sharon F. Freedman
Corresponding author
Correspondence to Sharon F. Freedman.
Ethics declarations
Competing interests
The authors declared the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: MAE is a site principal investigator for a Viridian clinical trial. SFF has a device on loan from Olleyes (Summit, NJ). BW has research funding from Knights Templar and is part of the editorial team at Scientific Reports. NP, JL, and ZS (current or former research coordinators) are or were supported through funding from Saving Kids’ Sight Foundation and the Lions Eye Foundation. All other authors declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.
Ethical approval
This study was approved by Duke University’s Institutional Review Board (Pro00109426). Written informed consent was obtained from the parent or guardian of all participants, and children provided verbal informed assent, with children 12 years and older providing written assent. All research activity complied with the Declaration of Helsinki and was in accordance with the Health Insurance Portability and Accountability Act (HIPAA). The study adhered to the tenets of the Declaration of Helsinki.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Tillit, S.M., Piryani, N., Liu, J. et al. Automated perimetry in children with suspected and known glaucoma: virtual reality versus tabletop. Sci Rep (2026). https://doi.org/10.1038/s41598-026-80649-0
Received: 28 September 2026
Accepted: 10 November 2026
Published: 18 November 2026
DOI: https://doi.org/10.1038/s41598-026-80649-0
Keywords
来源:Nature 健康护理主题 · nature.com