RELAX 是一种负担感知优化框架,通过减少训练中预测不稳定样本的影响来改善校准。在眼科、组织病理学、神经影像学和胸部X光四个医学影像数据集中,RELAX 降低了预期校准误差和最大校准误差,同时保持了相似的诊断准确性。这项研究建议,在训练过程中考虑预测稳定性可以提高临床AI系统的可靠性,而无需额外的推理成本。

正文

Scientific Reports (2026) Cite this article

We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.

Abstract

Accurate and well-calibrated confidence estimates are essential for the safe use of artificial intelligence (AI) in clinical imaging workflows, where overconfident errors can directly affect diagnostic decisions and patient outcomes. Conventional training objectives such as cross-entropy often encourage uniformly high confidence across all samples, leading to substantial miscalibration, particularly on rare pathologies, heterogeneous patient populations, and inherently ambiguous cases. Recent work addresses this by modifying loss functions to improve calibration, yet these approaches typically penalize errors equally across samples, including intrinsically difficult or noisy examples, which can contribute to suboptimal calibration. To address this limitation, we introduce the Perpetual Burden Score (PBS), a measure of sample difficulty derived from prediction instability observed during training. Building on PBS, we propose RELAX, a burden-aware optimization framework that down-weights chronically unstable (hard) samples during training, thereby reducing their influence on confidence formation. Across four medical imaging datasets spanning ophthalmology, histopathology, neuroimaging, and chest radiography, RELAX demonstrates overall improvements in calibration, while maintaining comparable diagnostic accuracy. For example, across 5 different architectural configurations on the ophthalmology dataset, on average, RELAX reduces Expected Calibration Error (ECE) and Maximum Calibration Error (MCE) by 2.38% and 11.72%, respectively, while the reduction in F1-score is observed at 0.86%. These findings suggest that incorporating prediction stability into the training process can improve the reliability of confidence estimates without additional inference-time cost. As an architecture-agnostic and lightweight framework, RELAX provides a practical approach for enhancing the trustworthiness of clinical AI systems.

Funding

No funding was received for this work.

Author information

Authors and Affiliations

  1. Advanced Technology Group, Science and Technoloy Organization, GE HealthCare, Bangalore, India

    Rohan Raju Dhanakshirur, Raghunathan Selvam, Rahul Venkataramani, Prasad Sudhakara Murthy & Chandan Kumar Aladahalli

Authors

  1. Rohan Raju Dhanakshirur
  2. Raghunathan Selvam
  3. Rahul Venkataramani
  4. Prasad Sudhakara Murthy
  5. Chandan Kumar Aladahalli

Corresponding author

Correspondence to Rohan Raju Dhanakshirur.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Dhanakshirur, R.R., Selvam, R., Venkataramani, R. et al. RELAX: Reliability enhancement by limiting adverse eXertions. Sci Rep (2026). https://doi.org/10.1038/s41598-026-70532-3

Download citation

  • Received: 16 February 2026

  • Accepted: 03 September 2026

  • Published: 03 November 2026

  • DOI: https://doi.org/10.1038/s41598-026-70532-3