可解释 AI 在埃塞俄比亚早期筛查风湿性心脏病中的应用
Interpretable AI for echocardiography-based early screening of rheumatic heart disease in Ethiopia: a cost-effective strategy to tackle a persistent global health disparity
该研究开发了一种可解释的人工智能框架,利用超声心动图影像自动化早期筛查风湿性心脏病(RHD),特别是在资源有限的埃塞俄比亚地区。通过训练和比较两种AI模型,该框架在独立测试集中实现了高精度和召回率,表明其在低资源环境中的潜在应用价值。该系统通过可视化分割边界、多普勒血流模式和解剖测量,提高了临床透明度,有助于减少对稀缺专科专家的依赖,推动成本效益高的筛查项目。
Abstract
Rheumatic heart disease (RHD) is a serious condition that develops from untreated streptococcal throat infections and causes long-term damage to the heart valves. Although it is become rare in wealthier countries, it still affects many people in low- and middle-income countries (LMICs), like sub-Saharan Africa, where fragmented healthcare infrastructure and limited access to specialized diagnostics exacerbate diagnostic delays. This study presents an interpretable artificial intelligence (AI) framework designed to automate early RHD screening using echocardiographic imaging, with a focus on addressing critical diagnostic gaps in resource-constrained settings such as Ethiopia.
Our study explores how Interpretable AI based approach can help identify early signs of RHD using echocardiographic images, primarily mitral regurgitation (MR). Specifically, we focus on detecting mitral regurgitation in two views (Apical five chamber (AP5) and Parasternal long axis (PSLAX) views) during the heart’s systolic cycle and measuring the thickness of the anterior mitral valve leaflet (AMVL) from the PSLAX view as part of the old criteria. To do this, we trained and compared two AI models to segment the left atrium (LA) and mitral valve (MV) using annotated echocardiographic datasets. By tracking volume changes in the segmented LA, we identified the frames corresponding to the systolic cycle. To detect MR, which is a key pathological hallmark of RHD, we then overlaid Color Doppler blood flow information on the segmented LA regions of the systolic frames. Additionally, the MV segmentation model was used to measure the AMVL thickness during systole, a critical morphological indicator of chronic valvular damage which was not part of our primary focus. Importantly, this AI framework was developed primarily for the detection of World Heart Federation (WHF) significant MR. While AMVL thickness was examined as an additional morphological parameter, its measurement was performed during systole for methodological convenience and has not been validated for the assessment of mitral stenosis. Furthermore, the framework does not evaluate restricted mitral leaflet motion. Therefore, leaflet thickness measurements should be regarded as exploratory findings and not as diagnostic outputs of the proposed system.
Trained on annotated echocardiographic datasets and tested on an independent pilot test set of real-world scans from Ethiopian regional hospitals (patients not seen during training or validation), the AI model demonstrated promising results, achieving precision (1.0), recall (0.7), F1-score (0.82), and accuracy (0.7) metrics that underscore its potential for reliable deployment in low-resource environments. The system’s interpretable design, which visualizes segmentation boundaries, Doppler flow patterns, and anatomical measurements, prioritizes clinical transparency, enabling healthcare workers to validate AI outputs against familiar diagnostic benchmarks. By automating labor-intensive echocardiographic analyses, this AI-driven strategy could revolutionize early RHD detection in LMICs, reducing reliance on scarce specialist expertise and paving the way for scalable, cost-effective screening programs. Our findings highlight the transformative role of context-specific AI solutions in bridging global health inequities.
Acknowledgements
We would like to acknowledge all the volunteer students who participated in the screening program and Kidus Petros hospital cardiac center for letting us use the echocardiography machine. We would also appreciate GCH for the test echocardiography recordings. We also like to mention the active participation and facilitation of medical doctors, nurses and interns from KPSH.
Funding
No external funding: The authors declare that this research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Author information
Authors and Affiliations
Ethiopian Artificial Intelligence Institute, 40782, Addis Ababa, Ethiopia
Daniel Moges Tadesse, Demeke Mekonnen, Olyad Mulugeta Gonfa, Samuel Rahimeto Kebede, Fraol Gelana Waldamichael, Taye Girma Debele & Hiwot Taye Mekonnen
Kidus Petros Specialized Hospital, Addis Ababa, Ethiopia
Demeke Mekonnen
College of Engineering, Debreberhan University, 445, Debreberhan, Ethiopia
Samuel Rahimeto Kebede
College of Electrical and Mechanical Engineering, Addis Ababa Science and Technology University, 120611, Addis Ababa, Ethiopia
Taye Girma Debele
Authors
- Daniel Moges Tadesse
- Demeke Mekonnen
- Olyad Mulugeta Gonfa
- Samuel Rahimeto Kebede
- Fraol Gelana Waldamichael
- Taye Girma Debele
- Hiwot Taye Mekonnen
Corresponding authors
Correspondence to Daniel Moges Tadesse, Demeke Mekonnen or Olyad Mulugeta Gonfa.
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Tadesse, D.M., Mekonnen, D., Gonfa, O.M. et al. Interpretable AI for echocardiography-based early screening of rheumatic heart disease in Ethiopia: a cost-effective strategy to tackle a persistent global health disparity. Sci Rep (2026). https://doi.org/10.1038/s41598-026-79181-y
Received: 15 September 2025
Accepted: 30 October 2026
Published: 02 November 2026
DOI: https://doi.org/10.1038/s41598-026-79181-y
Keywords
来源:Nature 健康护理主题 · nature.com