跳到正文
原文
Nature 健康护理主题·· 7 天前AI 评分20

后方固定设计对使用透明矫正器进行下前牙内推的初始生物力学效应:三维有限元分析

Biomechanical effects of posterior attachment design on mandibular incisor intrusion with clear aligners: a three-dimensional finite element analysis

AI 导读

该研究通过三维有限元分析评估了不同后方固定设计在使用透明矫正器进行下前牙内推时的初始生物力学效应。研究发现,不同固定设计对牙齿和矫正器的初始生物力学响应有显著影响,但这些结果仅描述了初始机械行为,不能直接作为临床保留、稳定或治疗效果的证据。

正文

We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.

Abstract

This study evaluated the initial biomechanical effects of different posterior attachment designs during mandibular incisor intrusion with clear aligners using three-dimensional finite element analysis. A mandibular half-arch finite element model was constructed from computed tomography data. Five models were evaluated: no attachment (NA), horizontal rectangular attachment (HRA), gingivally beveled horizontal rectangular attachment (GB-HRA), occlusally beveled horizontal rectangular attachment (OB-HRA), and modified dome-shaped attachment (MDA). Attachments were placed on the mandibular canines and premolars. A 0.2-mm intrusive activation was simulated through an interference fit between the mandibular central and lateral incisors and the corresponding internal surfaces of the clear aligner. Directional dental displacement, aligner displacement and Von Mises stress, attachment stress, contact pressure, aligner–attachment contact area, and periodontal ligament stress were evaluated. Posterior attachment design influenced the initial biomechanical responses of the mandibular teeth and clear aligner. The HRA model produced substantial incisal-edge displacement in the intrusive direction with relatively limited reactive extrusion in the canine–premolar region. The MDA model exhibited the greatest incisal-edge displacement in the intrusive direction, the lowest aligner displacement, the highest aligner–attachment contact ratio, and the lowest attachment stress. However, it also produced the highest aligner and periodontal ligament Von Mises stresses and pronounced reactive canine–premolar extrusion. The GB-HRA model exhibited the highest attachment stress and contact pressure. Posterior attachment designs produced distinct initial biomechanical responses during simulated mandibular incisor intrusion. The HRA model demonstrated a more favorable balance between anterior incisal-edge displacement in the intrusive direction and limited posterior extrusion, whereas the MDA model exhibited reduced aligner displacement and increased aligner–attachment contact accompanied by higher stress concentrations and reactive extrusion. These findings characterize initial mechanical behavior and should not be interpreted as direct evidence of clinical retention, stability, or treatment effectiveness.

Acknowledgements

None.

Funding

This research received no external funding.

Author information

Authors and Affiliations

  1. Department of Orthodontics, Faculty of Dentistry, Ankara University, Emniyet Mahallesi, İncitaşı Sokak, 06560, Yenimahalle, Ankara, Turkey

    Nursima Gökmen Çakır, Meyra Durmaz, Merve Berika Kadıoğlu & Meliha Rübendiz

Authors

  1. Nursima Gökmen Çakır
  2. Meyra Durmaz
  3. Merve Berika Kadıoğlu
  4. Meliha Rübendiz

Corresponding author

Correspondence to Meyra Durmaz.

Ethics declarations

Competing interests

The authors declare no competing interests.

Consent for publication

Not applicable.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Çakır, N.G., Durmaz, M., Kadıoğlu, M.B. et al. Biomechanical effects of posterior attachment design on mandibular incisor intrusion with clear aligners: a three-dimensional finite element analysis. Sci Rep (2026). https://doi.org/10.1038/s41598-026-80954-8

Download citation

  • Received: 30 August 2026

  • Accepted: 12 November 2026

  • Published: 13 November 2026

  • DOI: https://doi.org/10.1038/s41598-026-80954-8

Keywords

来源:Nature 健康护理主题 · nature.com