Abstract

Background

To comparatively evaluate the predictive accuracy of Lenstar 900, IOL Master 700, OptiWave refractive analysis (ORA) and a modified Placido topography method in patients undergoing cataract surgery following myopic laser-assisted in situ keratomileusis (LASIK).

Methods

A cohort of 62 post-myopic LASIK eyes from 37 patients was enrolled. Six methods were employed to estimate intraocular lens (IOL) power: Lenstar Barrett true K (BTK), Lenstar Shammas, IOL Master BTK, IOL Master BTK with total keratometry (TK), ORA and a modified Placido topography method.

Results

Mean prediction errors and mean absolute errors were lowest to highest for the modified Placido topography method, IOL Master BTK with TK and IOL Master BTK, respectively. The IOL Master BTK, Lenstar BTK and ORA method did not significantly differ from each other. All methods outperformed Lenstar Shammas. At 2 months postoperatively, the modified Placido topography method had the highest percentages of eyes with manifest absolute prediction errors within 0.50 and 1.00 D (91.9%, 100%), followed by IOL Master BTK with TK (67.7%, 100%), IOL Master BTK (62.9%, 95.2%), ORA (54.8%, 95.2%), Lenstar BTK (53.2%, 95.2%) and Lenstar Shammas (38.7%, 67.7%).

Conclusion

The BTK formula was highly accurate in predicting IOL power for patients undergoing cataract surgery after myopic LASIK. However, variations in keratometry values can influence outcomes. In this study, the modified Placido topography method was the most accurate, followed by IOL Master BTK with TK, IOL Master BTK, ORA, Lenstar BTK and Lenstar Shammas.

This is a preview of subscription content, access via your institution

Access options

Access through your institution

Subscribe to this journal

Receive 18 print issues and online access

251,40 € per year

only 13,97 € per issue

Buy this article

  • Purchase on SpringerLink
  • Instant access to the full article PDF.

39,95 €

Prices may be subject to local taxes which are calculated during checkout

Additional access options:

Fig. 1: The modified Placido topography method had the highest percentage of eyes achieving MAE within 0.25, 0.50 and 1.00 D.

Similar content being viewed by others

Data availability

The data that support the findings of this study are available from the corresponding author upon reasonable request.

References

  1. Chan CC, Hodge C, Lawless M. Calculation of intraocular lens power after corneal refractive surgery. Clin Exp Ophthalmol. 2006;34:640–4.

    Article  PubMed  Google Scholar 

  2. Hodge C, McAlinden C, Lawless M, Chan C, Sutton G, Martin A. Intraocular lens power calculation following laser refractive surgery. Eye Vis. 2015;2:7.

    Article  Google Scholar 

  3. Jarade EF, Abi Nader FC, Tabbara KF. Intraocular lens power calculation following LASIK: determination of the new effective index of refraction. J Refract Surg. 2006;22:75–80.

    Article  PubMed  Google Scholar 

  4. Savini G, Hoffer KJ, Carbonelli M, Barboni P. Scheimpflug analysis of corneal power changes after myopic excimer laser surgery. J Cataract Refract Surg. 2013;39:605–10.

    Article  PubMed  Google Scholar 

  5. Aramberri J. Intraocular lens power calculation after corneal refractive surgery: double-K method. J Cataract Refract Surg. 2003;29:2063–8.

    Article  PubMed  Google Scholar 

  6. Savini G, Hoffer KJ, Carbonelli M, Barboni P. Intraocular lens power calculation after myopic excimer laser surgery: clinical comparison of published methods. J Cataract Refract Surg. 2010;36:1455–65.

    Article  PubMed  Google Scholar 

  7. Shammas HJ, Shammas MC, Garabet A, Kim JH, Shammas A, LaBree L. Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis. Am J Ophthalmol. 2003;136:426–32.

    Article  PubMed  Google Scholar 

  8. Yesilirmak N, Palioura S, Culbertson W, Yoo SH, Donaldson K. Intraoperative wavefront aberrometry for toric intraocular lens placement in eyes with a history of refractive surgery. J Refract Surg. 2016;32:69–70.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Fram NR, Masket S, Wang L. Comparison of intraoperative aberrometry, OCT-based IOL formula, Haigis-L, and Masket formulae for IOL power calculation after laser vision correction. Ophthalmology. 2015;122:1096–101.

    Article  PubMed  Google Scholar 

  10. Lin HY, Kao ST, Chen S, Chuang YJ, Lin PJ. Comparing clinical outcomes of OptiWave refractive analysis, Lenstar, and surgeon’s modified method for intraocular lens power calculation in Asian eyes. Sci Rep. 2023;13:14447.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  11. Yeo TK, Heng WJ, Pek D, Wong J, Fam HB. Accuracy of intraocular lens formulas using total keratometry in eyes with previous myopic laser refractive surgery. Eye. 2021;35:1705–11.

    Article  PubMed  Google Scholar 

  12. Gale RP, Saldana M, Johnston RL, Zuberbuhler B, McKibbin M. Benchmark standards for refractive outcomes after NHS cataract surgery. Eye. 2009;23:149–52.

    Article  CAS  PubMed  Google Scholar 

  13. Brogan K, Diaper CJM, Rotchford AP. Cataract surgery refractive outcomes: representative standards in a National Health Service setting. Br J Ophthalmol. 2019;103:539–43.

    Article  PubMed  Google Scholar 

  14. Abulafia A, Hill WE, Koch DD, Wang L, Barrett GD. Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia. J Cataract Refract Surg. 2016;42:363–9.

    Article  PubMed  Google Scholar 

  15. Wang L, Tang M, Huang D, Weikert MP, Koch DD. Comparison of newer intraocular lens power calculation methods for eyes after corneal refractive surgery. Ophthalmology. 2015;122:2443–9.

    Article  PubMed  PubMed Central  Google Scholar 

  16. McCarthy M, Gavanski GM, Paton KE, Holland SP. Intraocular lens power calculations after myopic laser refractive surgery: a comparison of methods in 173 eyes. Ophthalmology. 2011;118:940–4.

    Article  PubMed  Google Scholar 

  17. Savini G, Hoffer KJ. Intraocular lens power calculation in eyes with previous corneal refractive surgery. Eye Vis. 2018;5:18.

    Article  Google Scholar 

  18. Abulafia A, Barrett GD, Rotenberg M, Kleinmann G, Levy A, Reitblat O, et al. Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: comparison of formulas and methods. J Cataract Refract Surg. 2015;41:548–56.

    Article  PubMed  Google Scholar 

  19. Ianchulev T, Hoffer KJ, Yoo SH, Chang DF, Breen M, Padrick T, et al. Intraoperative refractive biometry for predicting intraocular lens power calculation after prior myopic refractive surgery. Ophthalmology. 2014;121:56–60.

    Article  PubMed  Google Scholar 

  20. Chen AJ, Long CP, Lu T, Garff KJ, Heichel CW. Accuracy of intraoperative aberrometry versus modern preoperative methods in post-myopic laser vision correction eyes undergoing cataract surgery with capsular tension ring placement. Graefes Arch Clin Exp Ophthalmol. 2024;262:1545–52.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

This manuscript was edited by Wallace Academic Editing.

Funding

This research did not receive any specific grant from funding agencies in the public, commercial or not-for-profit sectors.

Author information

Authors and Affiliations

  1. Universal Eye Center, Zhong-Li, Taiwan, ROC

    Hung-Yuan Lin

  2. Universal Eye Center, Jinghua, Taiwan, ROC

    Chia-Chieh Hsiao

  3. Universal Eye Center, Taoyuan Arts District, Taoyuan, Taiwan, ROC

    Ya-Jung Chuang

  4. Universal Eye Center, Taipei, Taiwan, ROC

    Pi-Jung Lin

Authors

  1. Hung-Yuan Lin
  2. Chia-Chieh Hsiao
  3. Ya-Jung Chuang
  4. Pi-Jung Lin

Contributions

H-YL contributed to data collection, conceived the study and drafted the manuscript. C-CH contributed to data collection, interpreted the data, drafted the manuscript and finalized the manuscript. He also served as the corresponding author. YJC assisted in patient recruitment, data analysis and manuscript revision. P-JL contributed to study design, literature review and critical revision of the manuscript.

Corresponding author

Correspondence to Chia-Chieh Hsiao.

Ethics declarations

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lin, HY., Hsiao, CC., Chuang, YJ. et al. Enhanced keratometry for IOL power calculation after myopic LASIK: a multi-device comparison. Eye (2026). https://doi.org/10.1038/s41433-026-04908-0

Download citation

  • Received: 16 June 2025

  • Revised: 26 July 2026

  • Accepted: 11 September 2026

  • Published: 01 October 2026

  • Version of record: 01 October 2026

  • DOI: https://doi.org/10.1038/s41433-026-04908-0

来源:Nature 健康护理主题 · nature.com