Measurement fidelity and external validation of automated breast DCE-MRI segmentation
研究开发了一种增强感知的三维MedNeXt框架,并在多队列设计中评估了其测量准确性和外部有效性。结果显示,自动化分割在多个队列中的表现良好,支持其在乳腺癌研究中的应用。
- Article
- Open access
- Published: 14 November 2026
npj Digital Medicine (2026) Cite this article
We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.
Abstract
Automated breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) segmentation could facilitate quantitative tumor measurement, but geometric overlap alone does not establish the fidelity of mask-derived measurements. We developed an enhancement-aware three-dimensional MedNeXt framework with gated skip fusion and boundary supervision and evaluated it in a retrospective multi-cohort design spanning locked internal testing, source-held-out assessment, retrospective external validation, and radiologist review. Measurement fidelity was the primary endpoint. Across 521 paired internal-test and DUKE cases, median errors were 9.7% for tumor volume, 1.8 mm for 3D maximum surface diameter, and 10.2% for operational enhancement-defined volume, with corresponding ICCs of 0.97, 0.80, and 0.97. Median Dice was 0.831 internally and 0.823 in the DUKE source-held-out stratum, and was 0.812 and 0.806 in the BC-MRI-SEG and public BreastDCEDL_AMBL retrospective external-validation cohorts, respectively, using the frozen checkpoint without external-label tuning. No major correction was required for 78 of 80 masks in the blinded two-reader review. In 276 paired response-analysis cases, AUROC was 0.732 with automatic geometry and 0.757 with expert geometry (difference, −0.025; 95% CI, −0.095 to 0.045); discrimination non-inferiority was not demonstrated. These findings support automated segmentation as a starting point for radiologist-supervised retrospective quantitative research within the evaluated cohorts, while distinguishing measurement fidelity from downstream predictive equivalence.
Acknowledgements
Not applicable.
Funding
This work was supported by the Beijing Cancer Prevention & Treatment Society (Grant Nos. IZXUEYANZI 2022-1004 and IZXUEYANZI 2023-1003, to Yuanxi Huang), the China Primary Health Care Foundation (Grant No. cphcf-2023-019, to Yuanxi Huang), and the National High Level Hospital Clinical Research Funding and Cooperation Fund of CHCAMS Beijing & Langfang & SZCH (Grant No. CFA202503006, to Li Chen). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Author information
Author notes
These authors contributed equally: Chunlei Tan, Li Chen.
Authors and Affiliations
Department of Breast Surgery, Harbin Medical University Cancer Hospital, Harbin, PR China
Chunlei Tan, Shiyuan Zhang & Yuanxi Huang
Department of Breast Surgical Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, PR China
Li Chen
Department of Endoscope, Harbin Medical University Cancer Hospital, Harbin, PR China
Jinling Xu
Department of Diagnostic Radiology Division, Harbin Medical University Cancer Hospital, Harbin, PR China
Jian Zheng
Authors
- Chunlei Tan
- Li Chen
- Jinling Xu
- Jian Zheng
- Shiyuan Zhang
- Yuanxi Huang
Corresponding author
Correspondence to Yuanxi Huang.
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Tan, C., Chen, L., Xu, J. et al. Measurement fidelity and external validation of automated breast DCE-MRI segmentation. npj Digit. Med. (2026). https://doi.org/10.1038/s41746-026-03446-z
Received: 23 July 2026
Accepted: 13 October 2026
Published: 14 November 2026
DOI: https://doi.org/10.1038/s41746-026-03446-z
来源:Nature 健康护理主题 · nature.com