仪器化八字走测试的单次测试重复性及转向模式

Intra-session repeatability, turning laterality, and turning patterns during the instrumented figure-of-eight walk test

AI 导读

仪器化八字走测试(F8Wi)在单次测试中表现出良好的重复性(ICC = 0.85,CV = 16.5%),但首尾转向的重复性较差。转向模式受行走条件影响较小,而转向侧别影响不大。该测试可作为可靠的功能性评估工具,特别是在评估转向不对称性方面。

正文

Abstract

The figure-of-eight walk test (F8W) is a key component of the functional assessment of curved gait. A new instrumented methodology (F8Wi), combining a lumbar inertial measurement unit (IMU) and Doppler radar, has demonstrated good test-retest repeatability over time. However, the intra-session repeatability has not yet been investigated. Moreover, the literature remains contradictory regarding differences between right and left turns. Therefore, this study had two objectives: to evaluate the intra-session repeatability of a F8Wi protocol and to compare differences in turning time and gait parameters according to turning laterality, trial number, and walking condition. Twenty-two participants completed a F8Wi test comprising four loops, including four left turns and four right turns. The test was performed under four conditions: shod at a comfortable (SC) and fast (SF) speed, and barefoot at a comfortable (BC) and fast (BF) speed. Several points of interest were identified with a Doppler radar and an inertial measurement unit (IMU): the start of speed deceleration (A), the start of body rotation (B), the peak angular acceleration (C), the end of body rotation (D), and the end of speed acceleration (E). The dependent variables were time intervals between AB, AD, AE, BD, and gait parameters measured during the turn defined by AE time: gait cadence, mean step and cycle time (left and right). The intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimal detectable change (MDC95%), and coefficient of variation (CV) assessed repeatability. ANOVAs and post hoc analyses were conducted to examine the main effects and interactions of turn laterality (left vs. right), trial number (1–8), and condition. The F8Wi test demonstrated good intra-session repeatability (on average: ICC = 0.85 and CV = 16.5%). However, the first and final turns were less repeatable and differed significantly from the other turns (p < 0.05). In contrast to the effect of walking condition, turn laterality had little influence. The F8Wi is a reliable functional assessment tool that needs to be explored in clinical assessment, particularly for evaluating turning asymmetries in timing and gait parameters. However, the first and final turns involve a distinct timing compared with the others. Walking conditions can also be adjusted to introduce different task constraints.

Acknowledgements

The authors would like to thank the participants for their efforts and enthusiasm for this study. They would also like to thank Benjamin Pâris, Caroline Nicol, Justin Regnaud, Karen Runge, and Lucas Depieds for their valuable help during the experiments.

Funding

Funding agency: ANR Number ANR-21-ESRE-004. It was carried out using HIPE Human Lab laboratory’s internal funds.

Author information

Author notes

  1. Samuel Trama and Adrien Mangini contributed equally to this work.

Authors and Affiliations

  1. CNRS, Université de Toulon, Institut Paoli- Calmettes, HIPE HumanLab, N°202324378C, Aix-Marseille Univ, 13284, Marseille, France

    Nicolas Prieur-Blanc, Samuel Trama, Adrien Mangini, Dorian Giraud, Denis Bertin, Arnaud Hays & Laurent Bensoussan

  2. Physical and Rehabilitation Medicine Department, APHM, South Marseille University Hospital, Marseille, France

    Nicolas Prieur-Blanc & Laurent Bensoussan

  3. CNRS, ISM (UMR 7287), Aix-Marseille Univ, Marseille, France

    Samuel Trama, Adrien Mangini & Denis Bertin

  4. Polytech Marseille, CNRS, IUSTI, Aix-Marseille Univ, Marseille, France

    Dorian Giraud

  5. CNRS, INT (UMR 7289), Aix-Marseille Univ, Marseille, France

    Laurent Bensoussan

  6. UGECAM Institut Universitaire de Réadaptation de Valmante Sud, Marseille, France

    Laurent Bensoussan

Authors

  1. Nicolas Prieur-Blanc
  2. Samuel Trama
  3. Adrien Mangini
  4. Dorian Giraud
  5. Denis Bertin
  6. Arnaud Hays
  7. Laurent Bensoussan

Corresponding author

Correspondence to Nicolas Prieur-Blanc.

Ethics declarations

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Prieur-Blanc, N., Trama, S., Mangini, A. et al. Intra-session repeatability, turning laterality, and turning patterns during the instrumented figure-of-eight walk test. Sci Rep (2026). https://doi.org/10.1038/s41598-026-79814-2

Download citation

  • Received: 25 March 2026

  • Accepted: 03 November 2026

  • Published: 06 November 2026

  • DOI: https://doi.org/10.1038/s41598-026-79814-2

Keywords

来源:Nature 健康护理主题 · nature.com