Leakage-controlled evaluation of vendor-aware three-dimensional missing-tooth localization in partially annotated multi-vendor cone-beam computed tomography

Leakage-controlled evaluation of vendor-aware three-dimensional missing-tooth localization in partially annotated multi-vendor cone-beam computed tomography

AI 导读

该研究评估了在部分标注多供应商锥形束计算机断层扫描(CBCT)中,物理空间重建、供应商对抗学习、密集教师-学生一致性及可靠性门控半监督方法的效果。在75次重复种子运行中,供应商对抗训练方法在锁定外测试中的灵敏度为0.793(95% CI 0.697–0.880),假阳性率为0.458。研究结果表明,该方法适用于特定的采集配置,但不证明存在一种普遍优越的半监督算法。

正文

We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.

Abstract

Three-dimensional missing-tooth localization in cone-beam computed tomography (CBCT) is challenged by partial annotation and scanner-dependent acquisition differences, while the benefit of unlabeled scans remains uncertain. We therefore conducted a leakage-controlled evaluation of physical-space reconstruction, vendor-adversarial learning, dense teacher–student consistency, and reliability-gated semi-supervision under common case-level partitions. After excluding two discordantly annotated exact duplicates, 83 labeled and 73 unlabeled scans with 111 objects were eligible. Across 75 repeated-seed runs, mean pFROC was 0.890 for pure supervision, 0.899 for vendor-adversarial training, and 0.872 for gated semi-supervision. In 50 post-lock exploratory benchmark runs, conventional 3D detection achieved 0.921 versus 0.886 for confidence-only Mean-Teacher-3D; the primary fold-blocked test was not significant (\(p=0.25\)). A post-lock exploratory cumulative gate ablation showed no pFROC change from uncertainty alone; full gating increased mean pseudo-label precision at confidence 0.70 to 0.826 while reducing coverage to 0.680, and modestly increased pFROC by 0.007 (\(p=0.50\)). After fold-specific calibration, vendor-adversarial training achieved the strongest locked outer-test operating point: sensitivity 0.793 (95% CI 0.697–0.880) at 0.458 false positives per volume (0.301–0.639). Post-lock leave-one-vendor-out results were heterogeneous: vendor-adversarial training was numerically strongest for Meyer and Newtom but not Kavo. Semi-supervised superiority was not demonstrated. The study is therefore positioned as an auditable evaluation of acquisition control and unlabeled-data use in multi-vendor CBCT rather than as evidence for a fundamentally novel or universally superior semi-supervised algorithm. These conclusions are specific to the investigated cohort and acquisition profiles and do not establish scanner-independent generalization.

Funding

The authors received no specific funding for this work.

Author information

Authors and Affiliations

  1. Department of Computer, Ar.C., Islamic Azad University, Arak, Iran

    Hana Asgari & Elham Mazinan

  2. Department of Computer Engineering, Ka.C., Islamic Azad University, Karaj, Iran

    Faraneh Zarafshan

  3. Institute of Artificial Intelligence and Social and Advanced Technologies, Ka.C., Islamic Azad University, Karaj, Iran

    Faraneh Zarafshan

  4. Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Tehran Medical Sciences, Tehran, Iran

    Ahmadreza Talaeipoor

Authors

  1. Hana Asgari
  2. Faraneh Zarafshan
  3. Ahmadreza Talaeipoor
  4. Elham Mazinan

Corresponding author

Correspondence to Faraneh Zarafshan.

Ethics declarations

Competing interests

The authors declare no competing interests.

Ethics and data governance

This secondary analysis used the publicly released, de-identified MORPH-CBCT dataset and involved no new participant recruitment or prospective data collection. According to the source data descriptor, the original data collection was approved by the Ethics Committee of Sir Run Run Shaw Hospital (Approval No. 20250222), all participants provided informed consent, and the approval covered CBCT data collection, three-dimensional reconstruction, and public sharing of the imaging dataset. The source study reports adherence to the Declaration of Helsinki and the CIOMS International Ethical Guidelines for health-related research involving humans, and the publicly released data were anonymized before sharing. The present analysis used only the public de-identified release and did not attempt re-identification.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Asgari, H., Zarafshan, F., Talaeipoor, A. et al. Leakage-controlled evaluation of vendor-aware three-dimensional missing-tooth localization in partially annotated multi-vendor cone-beam computed tomography. Sci Rep (2026). https://doi.org/10.1038/s41598-026-79069-x

Download citation

  • Received: 04 September 2026

  • Accepted: 29 October 2026

  • Published: 16 November 2026

  • DOI: https://doi.org/10.1038/s41598-026-79069-x