跳到正文
原文
Nature 健康护理主题·· 9 天前AI 评分35

正常步态对肩峰轨迹量化的影响

The effect of normal gait on acromion trajectory quantification

AI 导读

本研究通过运动捕捉技术分析65名受试者的正常步态下肩峰轨迹,发现矢状面轨迹具有显著的个体间差异,识别率高达84.62%,而冠状面轨迹的识别能力较弱。研究结果有助于上肢步态特征的识别与生物力学解释,支持多模态步态分析、临床评估和监控。

正文

We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.

Abstract

Shoulder motion is key to gait, and its quantitative trajectory offers insights for biomechanical evaluation and gait-based identification. This study explored how 3D acromion (SAE) trajectories affect intra-individual gait stability, inter-individual variability, and person identification. Using motion capture, 65 subjects’ SAE trajectories (normal walking) were projected onto sagittal and horizontal planes and analyzed via sway mode (α, vertical symmetry) and torsional mode (β, horizontal symmetry). A gait-specific dynamic time warping algorithm quantified trajectory similarity. Sagittal analysis identified 3 sway types (α < 1.00, = 1.00, > 1.00), and horizontal analysis distinguished 3 morphological patterns. Sagittal-plane SAE trajectories exhibited significant inter-subject variability, with Rank-1 recognition rates of 84.62% (L_SAE) and 81.54% (R_SAE), AUC values near 0.993 and EER below 5.00%. In contrast, horizontal-plane SAE trajectories had weaker discriminative capacity, with Rank-1 rates of 39.85% (L_SAE) and 39.54% (R_SAE), and EER of 20.61% and 22.11%, respectively. SAE analysis captured unique upper-body gait features, aiding identification or biomechanical interpretation and supporting multimodal gait analysis, clinical assessment, and surveillance.

Funding

This work was supported by the Special Funds for Basic Scientific Research and Development Program in the Central Non-profit Research Institutes of China under Grant (2024JB039); Open Project Fund of the Key Laboratory of Forensic Marks, Ministry of Public Security under Grant (2024FMKFKT09); Joint Funds of Hunan Provincial Natural Science Foundation (2026JJ81164); Special Project for Basic Work of Strengthening Police through Science and Technology of the Ministry of Public Security under Grant (2023JC18).

Author information

Authors and Affiliations

  1. Institute of Forensic Science, Ministry of Public Security China, Beijing, 100038, People’s Republic of China

    Lichang Guan, Yi Shi, Lei Feng, Jin Liu & Xuemei Jiang

  2. Hunan Police Academy, Changsha, 410138, Hunan, People’s Republic of China

    Lichang Guan, Nan Zhao & Zeng Zeng

  3. Institute of Automation Chinese Academy of Science, Beijing, 100190, People’s Republic of China

    Lichang Guan

Authors

  1. Lichang Guan
  2. Nan Zhao
  3. Zeng Zeng
  4. Yi Shi
  5. Lei Feng
  6. Jin Liu
  7. Xuemei Jiang

Corresponding authors

Correspondence to Lei Feng, Jin Liu or Xuemei Jiang.

Ethics declarations

Competing interests

The authors declare no competing interests.

Ethics statement

This study was approved by the Ethics Committee of the Institute of Forensic Science of China (Approval No. 2025-024), and was conducted in accordance with the principles of the Declaration of Helsinki. After being fully informed of the study aims, procedures, and potential risks, all participants provided written informed consent. The entire study was conducted in accordance with applicable ethical standards.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Guan, L., Zhao, N., Zeng, Z. et al. The effect of normal gait on acromion trajectory quantification. Sci Rep (2026). https://doi.org/10.1038/s41598-026-77172-7

Download citation

  • Received: 04 June 2026

  • Accepted: 19 October 2026

  • Published: 11 November 2026

  • DOI: https://doi.org/10.1038/s41598-026-77172-7

Keywords

来源:Nature 健康护理主题 · nature.com