深度学习筛查鼻腔结构性异常
Deep learning screening for severe nasal cavity structural abnormalities using endoscopic imaging
研究开发并评估了基于鼻内镜影像的深度学习辅助决策模型,用于识别由可见中隔-下鼻甲接触点定义的严重鼻腔结构性异常(S-NCSA)。使用双侧鼻腔ResNet34模型,平均诊断策略的准确率为85.5%(95% CI:82.6–88.1),敏感性为66.2%(57.8–73.9),特异性为90.6%(87.8–93.2)。
- Kojiro Hirano ORCID: orcid.org/0000-0002-4466-79531,
- Kouzou Murakami2,
- Kento Takeda3,
- Kaho Ukai3,
- Youngha Chang3 &
- …
- Nobuhiko Mukai3
We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.
Abstract
To develop and evaluate a deep learning–based decision-support model using nasal endoscopy videos to identify severe nasal cavity structural abnormality (S-NCSA), an image-based morphological category defined by a visible septum–inferior turbinate contact point, and to explore its potential for future triage applications in non-specialist settings. We retrospectively analyzed 628 nasal cavities from 317 patients; frames were assigned by board-certified otolaryngologists to the image-based morphological categories S-NCSA, nasal cavity structural abnormality (NCSA), or normal (NL), with S-NCSA defined by a visible septum-inferior-turbinate contact point. ImageNet-pretrained convolutional neural networks (CNNs)-Visual Geometry Group 16 (VGG16), 50-layer residual network (ResNet50), 18-layer three-dimensional residual network (3DResNet18), and 34-layer residual network (ResNet34)-were fine-tuned and evaluated with patient-level stratified four-fold cross-validation. Two ResNet34 strategies were compared: an Average-Diagnosis Model, for which the case-level score was the mean logit difference across frames and a positive mean logit difference indicated S-NCSA; and a Severe-Priority Model, for which a case was classified as S-NCSA when at least one frame was predicted as S-NCSA. In the bilateral-nasal ResNet34 analysis, the Average-Diagnosis strategy achieved 85.5% accuracy (95% confidence interval [CI], 82.6–88.1), 66.2% sensitivity (57.8–73.9), and 90.6% specificity (87.8–93.2). The Severe-Priority strategy yielded 79.5% accuracy (76.3–82.7), 84.6% sensitivity (78.1–90.2), and 78.1% specificity (74.2–81.8), indicating a sensitivity–specificity trade-off. Artificial intelligence (AI)-assisted nasal endoscopy can flag S-NCSA morphology, defined by a visible septum–inferior turbinate contact point, as decision support rather than autonomous clinical diagnosis. Because symptom severity and functional nasal patency were not evaluated, these findings should not be interpreted as validation of clinically severe nasal obstruction. The potential role of the Severe-Priority strategy in primary-care triage requires prospective clinical evaluation, while the Average-Diagnosis strategy may support image-based morphological assessment in specialist settings.
Acknowledgements
None.
Funding
None.
Author information
Authors and Affiliations
Department of Otorhinolaryngology–Head and Neck Surgery, Showa Medical University, 1-5-8 Hatanodai, Shinagawa-ku, Tokyo, 142-8666, Japan
Kojiro Hirano
Department of Radiology, Showa Medical University, Tokyo, Japan
Kouzou Murakami
Graduate School of Integrative Science and Engineering, Tokyo City University, Tokyo, Japan
Kento Takeda, Kaho Ukai, Youngha Chang & Nobuhiko Mukai
Authors
- Kojiro Hirano
- Kouzou Murakami
- Kento Takeda
- Kaho Ukai
- Youngha Chang
- Nobuhiko Mukai
Corresponding author
Correspondence to Kojiro Hirano.
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Hirano, K., Murakami, K., Takeda, K. et al. Deep learning screening for severe nasal cavity structural abnormalities using endoscopic imaging. Sci Rep (2026). https://doi.org/10.1038/s41598-026-80261-2
Received: 13 May 2026
Accepted: 05 November 2026
Published: 11 November 2026
DOI: https://doi.org/10.1038/s41598-026-80261-2