一分钟坐站测试在帕金森病中的信度与效度(Scientific Reports)
Reliability and validity of the one-minute sit-to-stand test in Parkinson’s disease
28 名帕金森病患者间隔 7 天两次完成 1STS,该测试与 2MWT 呈强正相关(r = 0.69, p < 0.01)、与 H&Y 分期呈中等负相关(r = −0.58, p < 0.01),重测信度优秀(ICC = 0.94, 95% CI: 0.86–0.97)。作者认为 1STS 可作为帕金森病功能表现的可靠且潜在有效的测量工具,临床场景下可考虑采用,但仍需进一步研究确认。
- Article
- Open access
- Published: 16 October 2026
Scientific Reports (2026) Cite this article
We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.
Abstract
To investigate the validity and test–retest reliability of the One-Minute Sit-to-Stand Test (1STS) in individuals with Parkinson’s disease (PD). Twenty-eight individuals with PD performed the 1STS twice with a 7-day interval. Concurrent validity was examined using correlations with the 2-Minute Walk Test (2MWT) and the Hoehn and Yahr (H&Y) stage. Test–retest reliability was assessed using the intraclass correlation coefficient (ICC). The 1STS showed a strong positive correlation with the 2MWT (r = 0.69, p < 0.01) and a moderate negative correlation with the H&Y stage (r = − 0.58, p < 0.01). Test–retest reliability was excellent (ICC = 0.94, 95% CI: 0.86–0.97). The 1STS is a reliable and potentially valid measure of functional performance in individuals with PD. It may be considered a practical option in clinical settings; however, further research is needed to confirm these findings.
Abbreviations
- 1STS:
-
One-Minute Sit-to-Stand Test
- 2MWT:
-
Two-Minute Walk Test
- H&Y:
-
Hoehn and Yahr stage
- PD:
-
Parkinson’s Disease
- ICC:
-
Intraclass Correlation Coefficient
- CI:
-
Confidence Interval
- SD:
-
Standard Deviation
- BMI:
-
Body Mass Index
Acknowledgements
We thank to Nihal Çimen and Zahra Jafari for technical support.
Funding
This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Author information
Authors and Affiliations
Department of Physiotherapy and Rehabilitation, School of Physical Therapy and Rehabilitation, Ahi Evran University, Kırşehir, Turkey
İsmail Ceylan, Mehmet Canlı, Büşra Kürtüncüoğlu, Meltem Yücel Ilgar & İrem Canlı
Department of Physiotherapy, Vocational School of Health Services, Ahi Evran University, Kırşehir, Turkey
Muhammed Samed Dalakçı & Büşra Aydın
Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, Muş Alparslan University, Central (Centrum) Campus, Mus, Turkey
Halil Alkan
Authors
- İsmail Ceylan
- Muhammed Samed Dalakçı
- Mehmet Canlı
- Büşra Kürtüncüoğlu
- Meltem Yücel Ilgar
- Büşra Aydın
- Halil Alkan
- İrem Canlı
Corresponding author
Correspondence to İsmail Ceylan.
Ethics declarations
Competing interests
The authors declare no competing interests.
Ethical approval
Ethical approval was ensured by the Muş Alparslan University Research Ethics Board (Approval No: 86743 − 2023/03–34). The study was conducted in accordance with the Declaration of Helsinki.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Ceylan, İ., Dalakçı, M.S., Canlı, M. et al. Reliability and validity of the one-minute sit-to-stand test in Parkinson’s disease. Sci Rep (2026). https://doi.org/10.1038/s41598-026-76425-9
Received: 26 May 2026
Accepted: 13 October 2026
Published: 16 October 2026
DOI: https://doi.org/10.1038/s41598-026-76425-9
Keywords
来源:Nature 健康护理主题 · nature.com