基于区域引导交叉注意力与视图GCN的可解释多视角超声心动图左向右分流病变分类
Region-guided cross-attention and view-GCN for interpretable multi-view echocardiographic classification of common left-to-right shunt lesions
本研究开发了一种整合空间区域引导交叉注意力与视图图卷积网络的可解释多视角融合框架,用于超声心动图自动分类常见的左向右分流性先天性心脏病。该模型在1,764例患者的开发队列中达到平均患者级AUC为0.976±0.015,在441例独立测试队列中总体多类别诊断准确率达97.05%,正常类别精确度为1.0000。
- Article
- Open access
- Published: 15 November 2026
Scientific Reports (2026) Cite this article
We’re sharing this article early to provide faster access to peer-reviewed, accepted research. It is citable and carries a permanent DOI. This version is subject to further edits and will be replaced automatically by the final Version of Record. All legal disclaimers apply.
Abstract
Echocardiography is the primary imaging modality for screening common congenital left-to-right shunt lesions; however, accurate diagnosis requires systematic integration of multiple standard views by experienced sonographers. Existing deep learning approaches typically analyze single views or rely on simple concatenation of multi-view features, which fail to capture anatomical relationships across imaging planes. Moreover, echocardiographic models are prone to shortcut learning, attending to background artifacts rather than clinically meaningful cardiac structures. We developed an interpretable end-to-end multi-view fusion framework integrating spatial region-guided cross-attention (RG-CA) and a view graph convolutional network (View-GCN). The framework was developed using a retrospective single-center cohort comprising 2,205 patients and 27,535 cine clips across four diagnostic categories: normal, atrial septal defect (ASD), ventricular septal defect (VSD), and patent ductus arteriosus (PDA). All dataset partitioning was performed at the patient level. The cohort was stratified into a development cohort of 1,764 patients (564 Normal, 576 ASD, 360 VSD, and 264 PDA) and an independent test cohort of 441 patients (141 Normal, 144 ASD, 90 VSD, and 66 PDA). All cine clips, sampled frames, and echocardiographic views from the same patient were retained within the same partition, and five-fold cross-validation was conducted exclusively within the development cohort. Five standard echocardiographic views were included: subcostal, apical four-chamber, parasternal short-axis, parasternal long-axis, and suprasternal long-axis. Cine clips were processed as frame-based multi-view image sets: representative frames were sampled from each clip, frame-level features were aggregated within each cine clip to obtain clip-level representations, clip-level representations belonging to the same echocardiographic view were further aggregated into a single view-level representation, and missing views were handled using zero-padding together with a view-availability mask. Zero-padding and the availability mask specify how the model processes missing views, but this architectural mechanism is not itself an empirical demonstration of missing-view robustness. The retained analysis did not include a controlled stress test in which one or more of the five views were systematically removed. View-GCN generated one final patient-level prediction per patient. No explicit temporal sequence model was used in the current implementation. Physician-annotated lesion masks were used only during model training as anatomical supervision for the mask-guided attention penalty (MGAP); no manually annotated mask is required during validation, testing, or clinical inference. Stratified five-fold cross-validation within the 1,764-patient development cohort yielded a reported mean patient-level AUC of 0.976 ± 0.015 for distinguishing normal cases from common left-to-right shunt lesions. In the independent test cohort, the model correctly classified 428 of 441 patients, yielding an overall multiclass diagnostic accuracy of 97.05%. The test cohort comprised 141 Normal, 144 ASD, 90 VSD, and 66 PDA patients. No ASD, VSD, or PDA cases were misclassified as normal, and the normal class achieved a precision of 1.0000. All reported test-set diagnostic-performance analyses were based on one aggregated patient-level prediction per patient rather than frame- or clip-level observations. Quantitative t-SNE/clustering and ablation performance claims are not made because the corresponding data partition, evaluation subset, denominator, and unit of analysis could not be verified. Attention maps are presented as qualitative illustrations only; quantitative Dice, IoU, and attention-mass measures are not reported. An exploratory L1-regularized analysis of 13 handcrafted grayscale intensity and texture descriptors ranked GLCM dissimilarity, homogeneity, and energy highest. This post hoc analysis was not based on a separately locked training-only subset and was not used as an input to the deep-learning classifier. The fold-specific configurations underlying the reported AUC could not be linked to a single defined training setup, and the exact configuration associated with the checkpoint used for the independent test predictions could not be verified. The proposed framework combines lesion-aware attention and graph-based multi-view reasoning to support automated diagnosis of common left-to-right shunt lesions using echocardiography. By using physician-defined anatomical regions as training-stage supervision rather than inference-stage inputs and integrating diagnostic evidence across multiple views, the training strategy was designed to encourage attention toward clinically relevant anatomical regions while supporting clinically oriented interpretability. The present results do not establish that reliance on non-anatomical artifacts or shortcut learning was quantitatively reduced. The model demonstrated high internal diagnostic accuracy, perfect normal-class precision, and qualitative attention visualizations and exploratory handcrafted intensity/texture-feature findings, suggesting its potential as an AI-assisted screening tool for common left-to-right shunt lesions.
Abbreviations
- A4C:
-
Apical four-chamber
- ASD:
-
Atrial septal defect
- AUC:
-
Area under the receiver operating characteristic curve
- CHD:
-
Congenital heart disease
- CNN:
-
Convolutional neural network
- GCN:
-
Graph convolutional network
- GLCM:
-
Gray-level co-occurrence matrix
- LASSO:
-
Least absolute shrinkage and selection operator
- LVEF:
-
Left ventricular ejection fraction
- MGAP:
-
Mask-Guided Attention Penalty
- PDA:
-
Patent ductus arteriosus
- PLAX:
-
Parasternal long-axis
- PPV:
-
Positive predictive value
- PSAX:
-
Parasternal short-axis
- RG-CA:
-
Region-guided cross-attention
- SBC:
-
Subcostal
- SLAX:
-
Suprasternal long-axis
- VSD:
-
Ventricular septal defect
Acknowledgements
Not applicable.
Funding
This study received no funding.
Author information
Author notes
Li Chen and Xuping Zhang: These authors contributed equally to this work and share first authorship.
Authors and Affiliations
Department of Ultrasound, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China
Li Chen
Department of Medical Ultrasound, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, No. 16766 Jingshi Road, Jinan, 250014, China
Xuping Zhang, Qian Li, Jing Guo & Peipei Zhang
Authors
- Li Chen
- Xuping Zhang
- Qian Li
- Jing Guo
- Peipei Zhang
Corresponding author
Correspondence to Peipei Zhang.
Ethics declarations
Competing interests
The authors declare no competing interests.
Ethics approval and consent to participate
This study was conducted in accordance with the Declaration of Helsinki. This study was approved by the ethics committees of The First Affiliated Hospital of Shandong First Medical University, with a waiver of informed consent.
Consent for publication
Not applicable.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Chen, L., Zhang, X., Li, Q. et al. Region-guided cross-attention and view-GCN for interpretable multi-view echocardiographic classification of common left-to-right shunt lesions. Sci Rep (2026). https://doi.org/10.1038/s41598-026-80624-9
Received: 11 July 2026
Accepted: 10 November 2026
Published: 15 November 2026
DOI: https://doi.org/10.1038/s41598-026-80624-9
Keywords
来源:Nature 健康护理主题 · nature.com