Nature 健康护理主题·· 22 天前AI 评分43

服装集成式形变驱动器用于辅助穿衣

A garment-integrated shape-changing actuator for facilitating dressing

AI 导读

一种嵌入长袖衬衫的扁平管气动驱动器可在穿衣时增加局部刚度、维持服装结构并扩大袖窿,机械评估显示其激活后袖窿阻力增加、袖子摩擦降低。32名参与者在正常及模拟偏瘫条件下测试,模拟优势臂损伤时穿衣时间显著缩短,主观穿衣容易度改善(p < 0.001)。模拟非优势臂损伤时未观察到客观改善,但受试者仍报告感知更容易。

正文

Abstract

Dressing is a fundamental activity of daily living that becomes challenging for individuals with motor impairments, particularly when garment twisting, wrinkling, and limited armhole space hinder smooth limb insertion. This study presents a garment-integrated shape-changing actuator designed to increase localized stiffness, preserve garment structure, expand the armhole, and reduce friction between the fabric and skin. Flat-tube pneumatic actuators were embedded into a long-sleeved shirt to dynamically maintain garment geometry during dressing. Mechanical evaluations showed that actuator activation increased armhole resistance and reduced sleeve friction compared with the inactive condition. A user study involving 32 participants under normal and simulated hemiplegic conditions revealed a significant reduction in dressing time when dominant-arm impairment was simulated, alongside improved subjective ratings of dressing ease (p < 0.001). Although objective improvements were not observed for non-dominant impairment, participants consistently reported enhanced perceived ease. These findings suggest that actively maintaining garment shape can facilitate dressing motions and reduce interaction barriers between the wearer and clothing. By supporting user participation rather than replacing it, the proposed approach highlights the potential of garment-integrated soft actuators as an interaction-level assistive technology to support independent dressing while preserving residual functional abilities.

Introduction

Dressing is a fundamental activity of daily living (ADL) and a critical determinant of independence following stroke. Individuals with hemiplegia frequently experience substantial difficulty performing upper-body dressing and often require caregiver assistance1,2. This dependency contributes to increased caregiver burden and reduced quality of life while also reflecting limitations in motor recovery and functional performance during rehabilitation3,4,5. Dressing has been reported to remain more challenging than many other ADL tasks even after rehabilitation, underscoring its importance as a clinical indicator of functional independence6.

Beyond motor impairment, practical difficulties also arise from the behavior of garments themselves. Clothing may twist, wrinkle, or collapse during limb insertion, and individuals with neurological deficits may struggle to correct these issues independently7. Design guidelines for garments intended for physically disabled individuals therefore emphasize ease of manipulation and structural support8. Facilitating independent dressing has also been shown to improve self-efficacy and promote participation in rehabilitation9. Together, these findings suggest that optimizing human-garment interaction may play a key role in enhancing dressing independence.

Robot-assisted dressing systems have demonstrated promising capabilities in garment manipulation and automated assistance10,11. Recent work has explored self-wearing adaptive garments that use soft actuators to autonomously unfurl and advance garments along the user’s limb during dressing12. However, most existing approaches are designed to enable a robot or garment system to dress the user, prioritizing task completion rather than supporting user autonomy or preserving residual functional abilities. Such assistance may inadvertently reduce opportunities for active participation, despite the clinical importance of maintaining motor function during rehabilitation. Although several devices have been proposed for dressing assistance, upper-body dressing remains particularly complex and physically demanding13. Expanding the armhole and maintaining garment structure are especially important for enabling smooth limb insertion. Prior work has explored fastener configurations to facilitate dressing in individuals with hemiplegia14; however, relatively little attention has been given to garment-integrated actuation for dressing assistance. Recent work has highlighted the need for assistive technologies that support user involvement instead of replacing their efforts entirely. To the best of our knowledge, few robot-assisted dressing devices have explicitly aimed to preserve users’ residual motor functions by enabling them to participate actively in the dressing process. Therefore, this study targets individuals who retain partial motor ability but experience difficulty performing upper-body dressing due to physical limitations, including those with hemiparesis, age-related motor decline, developmental conditions, or other disabilities, as they often rely on caregivers due to reduced fluency and smoothness of movement. Supporting these individuals requires assistive strategies that enhance performance without diminishing their remaining capabilities. Accordingly, rather than automating the dressing task, this study focuses on augmenting the garment itself to support independency while maintaining functional ability.

Textile-based soft robotic technologies have emerged as lightweight and wearable alternatives capable of supporting physical function15,16. Pneumatic actuators and artificial muscles have been widely explored for rehabilitation and assistive applications, enabling devices such as soft robotic gloves and elbow sleeves that augment limb motion17,18,19,20,21,22,23,24,25. Among these technologies, pouch motors provide printable and inflatable actuation but are primarily designed for contraction and may be less suitable for permanent integration into garments due to their thickness26,27,28. Bending actuators based on flat or pleated tube structures have demonstrated controlled curvature through inflation and offer greater compatibility with wearable integration29. Despite these advances, most wearable robotic systems focus on assisting body movement rather than modifying the garment to facilitate the task itself.

In contrast to autonomous dressing systems and wearable assistive devices that directly augment body movement, we propose a garment-integrated shape-changing actuator that assists dressing by actively maintaining garment geometry during limb insertion. Rather than automating the dressing process, the proposed approach is intended to assist dressing while allowing users to actively perform the task using their residual motor function. The system uses soft actuators to increase structural stability, expand the armhole opening, and reduce fabric collapse during limb insertion. By increasing localized stiffness, preserving structural shape, expanding the passage space for the limb, and reducing fabric-skin friction, the garment becomes an active assistive element. Given the influence of thermal and skin-related factors on tactile perception and manual performance30,31, reducing mechanical resistance at the garment interface may further improve dressing performance.

We hypothesized that actively preserving garment structure would facilitate dressing motions by preventing twisting and wrinkling while enlarging the available space for limb insertion. To test this hypothesis, we developed a long-sleeved garment embedded with flat-tube pneumatic actuators capable of dynamically increasing stiffness. Mechanical experiments were conducted to evaluate armhole stiffness and sleeve friction, followed by a user study involving participants under normal and simulated hemiplegic conditions to assess dressing performance and subjective usability.

Results

To evaluate whether garment-integrated actuation improves dressing mechanics and user performance, we conducted mechanical validation followed by controlled user experiments. Objective outcomes are summarized in Table 1, while subjective responses are presented in Tables 2 and 3.

System overview

We developed a garment-integrated actuation system designed to stabilize clothing geometry during dressing (Fig. 1). Flat-tube pneumatic actuators were embedded within a long-sleeved garment to actively preserve the armhole opening and reduce fabric deformation during limb insertion.

Fig. 1

Garment-integrated actuator system designed to maintain armhole geometry during dressing. (A) Overall view of the long-sleeved garment with embedded flat-tube pneumatic actuators. (B) Layout and pneumatic routing of the actuator regions placed at the armhole, sleeve, and underarm to support structural expansion and wrinkle suppression. (C) Fabrication process of the flat-tube actuator enabling a thin and compliant structure suitable for garment integration. (D) Working principle of the actuator showing bending upon air supply, which generates localized stiffness and forming the curved shape.

The overall garment with integrated actuators is shown in Fig. 1A. The actuators were positioned to provide structural support while maintaining baseline wearability. As illustrated in Fig. 1B, the layout divides the system into three functional regions: the armhole region to support opening expansion, the sleeve region to suppress wrinkling and guide arm movement, and the underarm region to enhance clearance during insertion.

Figure 1C presents the fabrication of the flat-tube actuator. The structure was designed to remain thin and compliant when unpressurized while enabling controlled deformation upon inflation, allowing seamless integration into everyday clothing without substantially altering garment flexibility. The working principle is illustrated in Fig. 1D. When the actuator is constructed using fabric sheets of different thicknesses, the softer side expands more under pressurization, shortening the distance between adjacent slits and causing the actuator to bend toward the softer side. This mechanically stabilizes the garment and minimizes collapse during dressing.

The sleeve section serves to reduce friction by stretching longitudinal wrinkles and maintaining the sleeve shape. It consists of two flat-tube actuators that expand when inflated, increasing stiffness. By stretching longitudinal wrinkles, friction is reduced, making it easier to pass the arm through the sleeve and pull it up to the shoulder. The underarm section maintains an expanded underarm space, providing additional clearance during dressing.

Rather than directly augmenting human motion, the proposed system assists dressing by maintaining garment geometry during limb insertion. By preserving armhole expansion and reducing fabric collapse, the actuator provides structural support while allowing the wearer to actively perform the dressing motion. This approach shifts assistance from body augmentation to garment modification, providing support only when needed while maintaining natural movement in the inactive state.

Mechanical validation

Armhole stiffness evaluation

To verify that actuator activation preserves armhole expansion, armhole stiffness was evaluated during controlled vertical compression (Fig. 2). Increased stiffness was expected to help maintain the geometric opening of the garment, preventing collapse and ensuring sufficient space for limb insertion. Force-displacement responses were recorded for both actuator states, with displacement defined as 0 mm at the initial contact between the load cell and the garment. Mean values (bold lines) and standard deviations (shaded regions) from three trials are presented.

In the deflated state, the armhole collapsed readily and provided minimal resistance, with an average force below 0.15 N. When inflated, the actuator preserved the armhole’s expanded geometry and required approximately 1.8 times greater load to achieve the same displacement. The average resistance force increased to approximately 0.38 N during the pressing interval, demonstrating that activation enhanced structural stability and prevented garment collapse. This magnitude of stiffness modulation indicates that the actuator can meaningfully alter garment mechanics rather than merely producing perceptual change.

Friction evaluation

To quantify whether expansion of the garment and retention of its expanded geometry facilitate dressing motion, sleeve friction was evaluated during horizontal linear displacement (Fig. 3). Actuator activation was expected to preserve sleeve opening and limit fabric collapse, thereby reducing mechanical resistance during arm insertion. Tensile load was recorded as the artificial skin was pulled horizontally, with displacement defined as 0 mm at the onset of pulling. Mean values (bold lines) and standard deviations (shaded regions) from three trials are shown for both actuator states.

Actuator activation reduced peak tensile load compared to the deflated condition, indicating that maintaining sleeve geometry decreased mechanical resistance during limb insertion and promoted smoother arm passage.

Fig. 2

Armhole stiffness evaluation under actuator deflated and inflated conditions. Displacement (mm) is plotted against applied load (N), where 0 mm corresponds to the initial contact between the load cell and the garment. Activation of the actuator preserved armhole geometry and increased resistance force compared to the deflated state. Bold lines represent mean values and shaded regions represent standard deviation (n = 3).

Fig. 3

Sleeve friction evaluation during linear displacement under actuator deflated and inflated conditions. Displacement (mm) is plotted against tensile load (N), where 0 mm corresponds to the initial pulling between the load cell and the artificial skin. Activation reduced peak tensile load, indicating decreased mechanical resistance during simulated arm insertion. Bold lines represent mean values and shaded regions represent standard deviation (n = 3).

Dressing motion evaluation

To evaluate whether garment-integrated actuation improves functional dressing performance, participants performed standardized dressing and undressing tasks following the workflow illustrated in Fig. 4A. Dressing and undressing times under normal condition, simulated dominant-side paralysis, and simulated non-dominant-side paralysis are shown in Fig. 4B. As shown in Table 1, dressing time decreased by approximately 14.3% under the simulated dominant-side paralysis condition when the actuator was activated. In contrast, only a small reduction was observed under simulated non-dominant-side paralysis (7.4%), and no statistically significant difference was detected in either the non-dominant or normal conditions. Meanwhile, undressing times showed minimal differences between actuator states across all conditions. The largest reduction occurring under dominant-side paralysis suggests that the actuator provides greater functional benefit when the primary dressing limb is compromised.

Consistent with the observed reduction in dressing time, subjective evaluations obtained through post-trial questionnaires are summarized in Table 2. Participants reported improved ease of dressing under simulated impairment conditions, while ease of dressing ratings in the normal condition remained comparable between actuator states. Detailed participant characteristics and full questionnaire responses are summarized in Table 3.

In contrast, ease of dressing ratings were slightly lower in the no-impairment condition, suggesting that structural assistance may be perceived as unnecessary when baseline dressing is already easy. Comfort-related metrics showed little change across conditions, indicating that the actuator did not introduce substantial physical burden. Collectively, these results demonstrate that preserving garment structure improves dressing performance while maintaining wearer comfort, with benefits becoming more pronounced as task difficulty increases.

Fig. 4

Experimental evaluation of dressing performance. (A) Procedure for the dressing and undressing tasks performed under normal, simulated dominant-side paralysis, and simulated non-dominant-side paralysis conditions. (B) Dressing and undressing time under actuator deflated and inflated conditions. Values represent mean ± standard deviation. The bracket denotes statistically significant differences between conditions (\(p < 0.05\)).

Table 1 Objective dressing-time outcomes across simulated conditions with the actuator deflated and inflated. Values represent mean ± standard deviation. Relative change indicates the direction of performance difference with activation. * denotes statistically significant differences between deflated and inflated conditions (\(p < 0.05\)).

Full size table

Regression analysis

Separate simple linear regression analyses were conducted to examine associations between subjective perceptual variables and differences in dressing or undressing time between deflated and inflated conditions.

Under simulated dominant-side paralysis, dressing-time difference was significantly associated with perceived ease of dressing (\(\beta\) = − 0.78, p = 0.02, \(R^2\) = 0.17), dryness (\(\beta\) = − 1.15, p = 0.04, \(R^2\) = 0.13), and smoothness (\(\beta\) = 2.67, p = 0.02, \(R^2\) = 0.17). Higher ratings of ease of dressing and dryness were associated with shorter dressing times, whereas higher smoothness ratings were associated with longer dressing times.

For undressing under simulated dominant-side paralysis, perceived ease of undressing was negatively associated with undressing-time difference (\(\beta\) = − 0.58, p = 0.03, \(R^2\) = 0.14), whereas warmth was positively associated (\(\beta\) = 1.05, p = 0.04, \(R^2\) = 0.13), indicating that higher warmth ratings corresponded to longer undressing times.

Under simulated non-dominant-side paralysis, dressing-time difference was negatively associated with perceived ease of dressing (\(\beta\) = − 0.78, p = 0.02, \(R^2\) = 0.17) and freedom (\(\beta\) = − 1.99, p = 0.02, \(R^2\) = 0.16), and positively associated with wrist circumference (\(\beta\) = 3.35, p = 0.02, \(R^2\) = 0.16). For undressing, higher ratings of ease of undressing were associated with shorter undressing times (\(\beta\) = − 0.70, p = 0.01, \(R^2\) = 0.21), while comfort showed a marginal association (\(\beta\) = − 0.60, p = 0.05, \(R^2\) = 0.12).

Discussion

This study demonstrates that actively stabilizing garment geometry can improve dressing performance, particularly when impairment affects the primary dressing limb. By embedding structural assistance directly within the garment, the proposed approach shifts the role of assistance from external robotic devices to the human–garment interface. Mechanical evaluation confirmed that actuator activation increased resistance to armhole collapse and reduced sleeve-related mechanical interference. These structural changes were associated with a significant reduction in dressing time under simulated dominant-arm impairment, indicating that preserving garment expansion plays a functional role when task difficulty is elevated.

No significant difference was observed in undressing time. This outcome likely reflects the removal strategy commonly adopted by participants, in which the sleeve was disengaged using trunk motion rather than relying on the geometric stability of the armhole. Because this maneuver involves less dependence on garment expansion or shape retention, the actuator’s structural contribution may have had limited influence during garment removal. This contrast suggests that garment stabilization is particularly relevant during limb insertion rather than extraction.

Subjective evaluations revealed improved perceived ease of dressing under simulated impairment conditions, even when objective time reductions were modest. This divergence indicates that perceived assistance may arise not only from measurable performance gains but also from smoother and more predictable garment interaction. By preventing fabric collapse and maintaining sleeve alignment, the actuator may reduce the need for corrective movements, thereby enhancing the wearer’s sense of control and usability.

The sensory experience associated with garment stabilization may further explain these findings. As shown in Table 3, differences between deflated and inflated conditions in items related to actuator presence, wearing motion, and wearing sensation were attenuated under simulated impairment compared to the normal condition. Although comfort ratings remained largely unchanged, participants under simulated paralysis appeared less sensitive to minor physical discomfort introduced by actuator activation. When motor function is constrained, successful task completion may take precedence over subtle tactile disturbances, shifting perceptual weighting from comfort toward functional assistance. By maintaining armhole expansion and limiting fabric collapse, the actuator likely produced a more predictable tactile interaction during limb insertion, reducing unexpected resistance and supporting smoother movement.

Regression analyses provided additional insight into the perceptual factors associated with performance changes. Under simulated dominant-side paralysis, shorter dressing times were associated with higher ratings of ease of dressing and dryness, whereas greater smoothness perception was associated with longer dressing times. For undressing, ease of undressing corresponded to shorter undressing times, while warmth perception was linked to longer undressing times. Under simulated non-dominant-side paralysis, reductions in dressing time were associated with greater perceived ease and freedom, whereas larger wrist circumference was associated with increased dressing time. Ease of undressing showed the strongest association with reduced undressing time, and comfort demonstrated a marginal relationship. Together, these findings suggest that subjective usability perception. Particularly, ease, dryness, freedom, and thermal sensation are closely linked to objective dressing performance, highlighting the importance of managing both structural stabilization and sensory interaction at the human-garment interface.

These findings suggest that assistive technologies need not rely solely on augmenting human biomechanics to improve functional performance. Modifying environmental interaction-specifically, the mechanical behavior of garments can meaningfully influence task fluency and perceived usability. By repositioning assistance at the human–garment interface, this work highlights an alternative pathway for supporting independence that preserves active motor engagement. Such interface-centered strategies may be broadly applicable to other activities of daily living where environmental resistance limits performance.

Several limitations should be acknowledged. First, impairment was simulated using healthy participants rather than individuals with motor impairments, which may not fully reflect the movement limitations and compensatory strategies encountered during dressing. This may have reduced the observable differences between conditions and potentially underestimated the benefits of actuator assistance. Nevertheless, the effectiveness of the proposed approach under conditions of constrained body movement remained evident. Further validation in the target user population would be needed in future work. Second, the order of actuator conditions was not randomized. Participants performed the dressing task first with the actuator deflated and then with the actuator inflated, which may have introduced learning or familiarization effects. Although the observed improvements are consistent with the intended function of the actuator, part of the performance gain may be attributable to increased familiarity with the task. Furthermore, the current prototype inflated both sides of the garment simultaneously and did not implement side-specific actuation. Future studies will employ randomized or counterbalanced condition orders and investigate side- and region-specific control strategies to optimize assistance according to user needs and impairment conditions.

From a practical perspective, several aspects of the proposed garment system require further development. A single shirt size was used to maintain consistent actuator placement and garment structure across all experimental conditions, although wrist circumference was associated with dressing performance. Size-adjustable garment designs and multiple garment sizes may improve fit and applicability across diverse users. In addition, the current prototype relied on an external pneumatic supply and was not intended for portable use. Preliminary testing demonstrated the feasibility of low-pressure operation using a miniature pneumatic pump and battery-powered system. Optimized actuator designs capable of achieving comparable expansion at lower operating pressures could enable compact pneumatic components, user-friendly control interfaces such as buttons or smartphone applications, and greater independence during dressing. As the actuator was fabricated primarily from fabric-based materials, it could be washed together with the garment. Preliminary observations indicated that the heat-sealed actuator body remained functional after a standard washing-machine cycle, although damage was observed at the rigid pneumatic tubing connections. The heat-sealed actuator was also susceptible to damage during the drying process due to its construction. Therefore, further investigation is required to develop robust garment-integration methods and detachable pneumatic interfaces for tubing (e.g., soft connectors32) while systematically evaluating durability, washability, maintenance requirements, and long-term usability.

Table 2 Subjective evaluation outcomes under actuator deflated and inflated conditions across simulated dressing conditions. Values are presented as mean ± standard deviation. Mean difference represents mean (Inflated) − mean (Deflated), with positive values indicating higher ratings with actuator activation. * denotes statistically significant differences between deflated and inflated conditions (\(p < 0.05\)).

Full size table

Table 3 Participant characteristics and questionnaire-based user feedback under three simulated conditions (Normal, Dominant-side paralysis, and Non-dominant-side paralysis; n = 32). Data are presented as mean (standard deviation). Subjective evaluations were obtained using structured questionnaires and rated on either 7-point (− 3 to 3) or 5-point (1 to 5) Likert scales, with higher values indicating stronger agreement or greater intensity as specified. p-values indicate within-condition comparisons between deflated and inflated states. *  indicates statistical significance (\({\textrm{p} < 0.05}\)).

Full size table

Methods

Garment system

In this study, pneumatic actuators were integrated into a commercially available long-sleeved cotton shirt (UNIQLO, 454337, size L) to create an inflatable garment capable of altering structural stiffness. The actuators were attached to the garment using washable double-sided fabric adhesive tape. Polyurethane tubing (4 mm outer diameter) was permanently secured to the actuator inlet using hot-melt adhesive and connected through a detachable T-joint fitting (Monotaro, MPUT-4) to a single pneumatic supply source serving both left and right sides of the flat-tube actuators. All actuator regions, including the armhole, sleeve, and underarm sections, were inflated simultaneously during operation. The total weight of the garment system, including the actuators, tubing, and T-joint fitting, was 295 g compared with 220 g for the unmodified shirt.

Armhole stiffness evaluation

Armhole stiffness was evaluated to determine whether actuator activation improved structural resistance during simulated arm insertion. The garment was fixed to a base using a towel clip, and a three-axis gantry robot equipped a load cell (IMADA, ZTS-DPU-50N) applied downward compression along the z-axis at a constant speed of 1.0 mm/s until reaching 80 mm displacement.

Applied force was recorded using a force gauge (IMADA, ZTS-i) at a sampling rate of 10 Hz. Measurements were repeated three times for both actuator states (deflated and inflated). Air pressure supplied by a compressor (KOBELCO, SG4AD IV) was maintained at 150 kPa during activation.

Sleeve friction evaluation

Sleeve friction was assessed by sliding an artificial skin sample horizontally inside the garment sleeve to quantify mechanical resistance during limb insertion. A 50 g artificial skin specimen (Beaulax Co., Ltd., H077-002) was displaced over 30 mm at a constant velocity of 1.0 mm/s using a gantry system. The garment was fixed to the experimental stage using two towel clips to prevent displacement during testing.

Tensile load was measured with a force gauge (IMADA, ZTS-i) at a sampling rate of 10 Hz while the artificial skin specimen was displaced by the gantry system. Trials were conducted three times under both actuator conditions. Inflation pressure was set to 150 kPa using an air compressor (EARTH MAN, ACP-13SLA).

Dressing motion evaluation

A total of 32 healthy adults (18 females, 14 males; mean age \(22.3 \pm 4.60\) years) participated in the study. The experimental protocol was approved by the Ethics Committee for Human Subject Research of the Institute of Science and Engineering, Kanazawa University (Approval number 2022-2). All experiments were performed in accordance with relevant guidelines and regulations. All participants received a detailed explanation of the study and provided written informed consent prior to participation.

Experiments were conducted under three conditions: normal, simulated dominant-side paralysis, and simulated non-dominant-side paralysis. Paralysis conditions was simulated using a hemiplegia experiencing set (Tokushu-iryo, Inc., 3010L) together with belts and elastic bands to restrict upper-limb movement.

The dressing and undressing procedure is shown in Fig. 4A. Participants were seated and placed the garment on their lap before each trial. Dressing began at a start signal with the actuator deactivated. After completing the task, participants rested for two minutes before performing the undressing task, which ended when the garment was returned to the lap.

Dressing and undressing times were recorded using a stopwatch. Participants subsequently completed a questionnaire evaluating subjective usability. The protocol was then repeated with the actuator activated.

Questionnaire

After each dressing and undressing trial, participants completed a questionnaire to assess subjective usability. The instrument included both 7-point and 5-point Likert-scale items depending on the construct being evaluated. The 7-point scale was used to capture perceptual responses with greater sensitivity, while the 5-point scale was applied to items requiring simpler evaluative judgments. For details on which questions were evaluated using a 7-point scale and which were evaluated using a 5-point scale, please refer to Table 3. The same questionnaire was administered under both actuator conditions (deflated and inflated) across all conditions.

Statistical analysis

Statistical analyses were performed using the Wilcoxon signed-rank test to compare actuator deflated and inflated conditions within each experimental task and simulated impairment condition. This nonparametric test was selected because several outcome measures consisted of ordinal Likert-scale responses and normality assumptions required for paired t-tests could not be guaranteed. Statistical significance was defined as \(p < 0.05\). Data are reported as mean ± standard deviation unless otherwise noted. All analyses were conducted using SPSS Statistics (IBM Corp., Armonk, NY, USA).

Data availability

The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.

References

  1. Suzuki, M. et al. Predicting recovery of upper-body dressing ability after stroke. Arch. Phys. Med. Rehabil. 87, 1496–1502. https://doi.org/10.1016/j.apmr.2006.07.267 (2006).

    Article  PubMed  Google Scholar 

  2. Suzuki, M. et al. Development of the upper-body dressing scale for a buttoned shirt. Am. J. Phys. Med. Rehabil. 87, 740–749. https://doi.org/10.1097/PHM.0b013e31818378b0 (2008).

    Article  PubMed  Google Scholar 

  3. Camak, D. J. Addressing the burden of stroke caregivers: a literature review. J. Clin. Nurs. 24, 2376–2382. https://doi.org/10.1111/jocn.12884 (2015).

    Article  PubMed  Google Scholar 

  4. Fujita, T., Sato, A., Togashi, Y., Kasahara, R. & Mori, Y. Relationship between dressing and motor function in stroke patients: a study with partial correlation analysis. J. Phys. Ther. Sci. 27, 3771–3774. https://doi.org/10.1589/jpts.27.3771 (2015).

    Article  PubMed  PubMed Central  Google Scholar 

  5. Walker, M. F. & Lincoln, N. B. Factors influencing dressing performance after stroke. J. Neurol. Neurosurg. Psychiatry 54, 699–701. https://doi.org/10.1136/jnnp.54.8.699 (1991).

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  6. Walker, C. M. & Walker, M. F. Dressing ability after stroke: a review of the literature. Br. J. Occup. Ther. 64, 449–454. https://doi.org/10.1177/030802260106400806 (2001).

    Article  Google Scholar 

  7. Sato, C. Rehabilitation technique and support of dressing and bathing activity for patients with cerebrovascular disease. Series of Articles on Rehabilitation Technique (2007).

  8. Matsuda, R. & Yokoyama, N. Clothes guidelines for physically disabled people. Sen’i Gakkaishi 59, 115–119. https://doi.org/10.2115/fiber.59.P_115 (2003).

    Article  Google Scholar 

  9. Hara, Y. & Segawa, D. A novel approach to achieving independent dressing in a patient with left hemispatial neglect-bilateral somatic integration with exercise instructions given in reverse order. Yamato Univ. Res. Bull. 2, 295–300 (2016).

    Google Scholar 

  10. Zhang, F. & Demiris, Y. Learning grasping points for garment manipulation in robot-assisted dressing. In 2020 IEEE International Conference on Robotics and Automation, 9114–9120. https://doi.org/10.1109/ICRA40945.2020.9196994 (2020).

  11. Zhang, F. & Demiris, Y. Visual-tactile learning of garment unfolding for robot-assisted dressing. IEEE Robot. Autom. Lett. 8, 5512–5519. https://doi.org/10.1109/LRA.2023.3296371 (2023).

    Article  Google Scholar 

  12. Kim, N. G. et al. Self-wearing adaptive garments via soft robotic unfurling. IEEE Robot. Autom. Lett. 11, 802–809. https://doi.org/10.1109/LRA.2025.3634909 (2026).

    Article  Google Scholar 

  13. Helps, T., Taghavi, M., Manns, S., Turton, A. J. & Rossiter, J. Easy undressing with soft robotics. In Wearable Robotics: Challenges and Trends, 79–90. https://doi.org/10.1007/978-3-319-96728-8_7 (2018).

  14. Huck, J. & Bonhotal, B. H. Fastener systems on apparel for hemiplegic stroke victims. Appl. Ergon. 28, 277–282. https://doi.org/10.1016/S0003-6870(97)00021-8 (1997).

    Article  CAS  PubMed  Google Scholar 

  15. Sanchez, V., Walsh, C. J. & Wood, R. J. Textile technology for soft robotic and autonomous garments. Adv. Func. Mater. 31, 2008278. https://doi.org/10.1002/adfm.202008278 (2021).

    Article  CAS  Google Scholar 

  16. Zannat, A., Uddin, M. N., Mahmud, S. T., Prithu, P. S. S. & Mia, R. Textile-based soft robotics for physically challenged individuals. J. Mater. Sci. 58, 12491–12536. https://doi.org/10.1007/s10853-023-08799-4 (2023).

    Article  CAS  Google Scholar 

  17. Abrar, T., Putzu, F., Konstantinova, J. & Althoefer, K. Epam: eversive pneumatic artificial muscle. In 2019 2nd IEEE International Conference on Soft Robotics, 19–24. https://doi.org/10.1109/ROBOSOFT.2019.8722787 (2019).

  18. Kurumaya, S., Nabae, H., Endo, G. & Suzumori, K. Design of thin mckibben muscle and multifilament structure. Sens. Actuators A 261, 66–74. https://doi.org/10.1016/j.sna.2017.02.033 (2017).

    Article  CAS  Google Scholar 

  19. Kurumaya, S., Nabae, H., Endo, G. & Suzumori, K. Active textile braided in three strands with thin mckibben muscle. Soft Rob. 6, 250–262. https://doi.org/10.1089/soro.2018.0078 (2019).

    Article  Google Scholar 

  20. Abe, T., Nabae, H., Endo, G. & Suzumori, K. Fabrication of “18 weave’’ muscles and their application to a soft power support suit for upper limbs using thin mckibben muscle. IEEE Robot. Autom. Lett. 4, 2532–2538. https://doi.org/10.1109/LRA.2019.2920201 (2019).

    Article  Google Scholar 

  21. Hawkes, E. W., Christensen, D. L. & Okamura, A. M. Design and implementation of a 300% strain soft artificial muscle. In 2016 IEEE International Conference on Robotics and Automation, 4022–4029. https://doi.org/10.1109/ICRA.2016.7487592 (2016).

  22. Belforte, G., Eula, G., Ivanov, A. & Sirolli, S. Soft pneumatic actuators for rehabilitation. Actuators 3, 84–106. https://doi.org/10.3390/act3010084 (2014).

    Article  Google Scholar 

  23. Yap, H. K., Lim, J. H., Nasrallah, F. & Yeow, C.-H. A fully fabric-based bidirectional soft robotic glove for assistance and rehabilitation of hand impaired patients. IEEE Robot. Autom. Lett. 2, 1383–1390. https://doi.org/10.1109/LRA.2017.2678540 (2017).

    Article  Google Scholar 

  24. Koh, T. H., Cheng, N., Yap, H. K. & Yeow, C.-H. Design of a soft robotic elbow sleeve with passive and intent-controlled actuation. Front. Neurosci. 11, https://doi.org/10.3389/fnins.2017.00581 (2017).

  25. Thalman, C. M., Lam, Q. P., Nguyen, P. H., Sridar, S. & Polygerinos, P. A novel soft elbow exosuit to supplement bicep lifting capacity. In 2018 IEEE/RSJ International Conference on Intelligent Robots and Systems, 6965–6971. https://doi.org/10.1109/IROS.2018.8594403 (2018).

  26. Niiyama, R., Rus, D. & Kim, S. Pouch motors: printable/inflatable soft actuators for robotics. In 2014 IEEE International Conference on Robotics and Automation, 6332–6337. https://doi.org/10.1109/ICRA.2014.6907793 (2014).

  27. Niiyama, R., Pearce, J. M., Rus, D. & Kim, S. Pouch motors: printable soft actuators integrated with computational design. Soft Rob. 2, 59–70. https://doi.org/10.1089/soro.2014.0015 (2015).

    Article  Google Scholar 

  28. Oh, N., Park, Y. J., Lee, S., Lee, H. & Rodrigue, H. Design of paired pouch motors for robotic applications. Adv. Mater. Technol. 4, https://doi.org/10.1002/admt.201900064 (2019).

  29. Dameitry, A. & Tsukagoshi, H. Lightweight underactuated pneumatic fingers capable of grasping various objects. In 2016 IEEE International Conference on Robotics and Automation, 2009–2014. https://doi.org/10.1109/ICRA.2016.7487347 (2016).

  30. Chen, W.-L., Shih, Y.-C. & Chi, C.-F. Hand and finger dexterity as a function of skin temperature, electromyography, and ambient condition. Hum. Factors 52, 426–440. https://doi.org/10.1177/0018720810376514 (2010).

    Article  PubMed  Google Scholar 

  31. Crucianelli, L. & Ehrsson, H. H. The role of the skin in interoception: a neglected organ?. Perspect. Psychol. Sci. 18, 224–238. https://doi.org/10.1177/17456916221094509 (2023).

    Article  PubMed  Google Scholar 

  32. Arai, N., Nishimura, T. & Watanabe, T. Variable-diameter connector with bistable structure for flat tube actuators. In 2025 IEEE 8th International Conference on Soft Robotics (RoboSoft), 1–8. https://doi.org/10.1109/RoboSoft63089.2025.11020968 (2025).

Download references

Funding

This work was partly supported by JST [Moonshot R&D] [Grant Number JPMJMS2034], JSPS KAKENHI Grant Number JP23H04343, and the TeSH GAP Fund Program Step 1 of the Startup Ecosystem Co-Creation Program, JST [Grant Number TeSH2026-17]. The funders have no role in study design, data collection and analysis, decision to publish or preparation of the manuscript.

Author information

Authors and Affiliations

  1. Faculty of Frontier Engineering, Institute of Science and Engineering, Kanazawa University, Kanazawa, 920-1192, Japan

    Kawinna Nipatphonsakun & Tetsuyou Watanabe

  2. Graduate School of Natural Science and Technology, Kanazawa University, Kanazawa, 920-1192, Japan

    Ikumi Hayashi

Authors

  1. Kawinna Nipatphonsakun
  2. Ikumi Hayashi
  3. Tetsuyou Watanabe

Contributions

K.N. supervised the research and wrote the manuscript, including restructuring the content, interpreting the results, and developing the discussion. I.H. conducted the experiments, performed the user study, and collected the data. T.W. conceptualized the study and provided overall supervision and research direction. All authors reviewed and approved the final manuscript.

Corresponding authors

Correspondence to Kawinna Nipatphonsakun or Tetsuyou Watanabe.

Ethics declarations

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nipatphonsakun, K., Hayashi, I. & Watanabe, T. A garment-integrated shape-changing actuator for facilitating dressing. Sci Rep 16, 35357 (2026). https://doi.org/10.1038/s41598-026-60789-z

Download citation

  • Received: 13 February 2026

  • Accepted: 30 June 2026

  • Published: 29 October 2026